G3 Display 006-00001GF                                             

 

 

4

 

Clayton Power R&D, s.r.o.                                                      006-00001DSF rev.003 

 

1

 

Features 

 

Remote control of up to four G3 combi or inverter 

 

Wide supply voltage range 8-35VDC 

 

Single wire communication with up to four G3 units 

 

Low power consumption >5mA in standby mode (without back light) 

 

Low sleep mode consumption >100uA 

 

Firmware update over PC 

2

 

Installation  

2.1

 

Safety instructions 

Installation must strictly follow the national safety regulations in compliance with the 
enclosure,  mounting,  creepage,  clearance,  casualty,  markings,  and  segregation 
requirements  of  the  end-use  application.  The  installation  must  be  performed  by 
professional  installer  only.  Switch  off  the  system and  check for  hazardous  voltages 
before  altering  any  connection! 

Ensure  that  both  units  are  switched  off  during  the 

wiring of G3 display to Inverter/Charger/Combi!

 

2.2

 

Wiring 

The  maximal  length  of  cables  between  the  G3  display  006-00001GF  and 
Inverter/Charger/Combi is 5 meters. Use the wire AWG18 with rating of 300VAC for 
the connections. The temperature rating of cables has to be minimum 80°C or higher 
(according to end-use application)  

2.3

 

Connectors Pinout and Location 

 

 

Figure 1: Location of connectors on rear panel of G3 Display 

 

 

 

 

Summary of Contents for G3 Display 006-00001GF

Page 1: ...G3 Display 006 00001GF USER S MANUAL Firmware version 1 02 05 Hardware version 1 03 ...

Page 2: ...errors which may occur The information may contain errors or inaccuracies and represents no commitment whatsoever Exclusion of liability Clayton Power shall in no event be liable for loss damages or costs arising from use of this Clayton Power product or in any way connected with faulty installation improper operation or incorrect utilization and maintenance Clayton Power shall in no event be liab...

Page 3: ...of Contents 1 Features 4 2 Installation 4 2 1 Safety instructions 4 2 2 Wiring 4 2 3 Connectors Pinout and Location 4 2 4 Connection to system 5 3 Functions 6 3 1 Keyboard function 6 3 2 Main Screen 6 3 3 Menu 7 3 3 1 Main menu 7 3 3 2 Genset menu 7 4 Label 8 5 G3 Display outline drawing 10 ...

Page 4: ...ance casualty markings and segregation requirements of the end use application The installation must be performed by professional installer only Switch off the system and check for hazardous voltages before altering any connection Ensure that both units are switched off during the wiring of G3 display to Inverter Charger Combi 2 2 Wiring The maximal length of cables between the G3 display 006 0000...

Page 5: ...on Output 1 Generator remote control Output 2 Output 3 Hall sensor output Input 1 Input 2 Mating connector type is MOLEX 0039012125 J4 J5 Pin Signal Description 1 2 3 4 5 6 TEMPX1 GND_TELE TEMPX1 SYNC_IN OUT DATA REMOTE OUT N A for Display User s GND Fused N A for Display N A for Display Single Wire Data communication Remote control of G3 Mating connector type is MOLEX 0900750031 Connectors J4 and...

Page 6: ...arge 3 1 Keyboard function Key Key Function Turn On Display and all connected units Turn Off Display and all connected units Scroll up in the menu list increase set value Scroll down in the menu list decrease set value Enter to the menu if pressed in main screen or escape from menu if pressed in menu Enter to the selected submenu save set value 3 2 Main Screen When menu is not active G3 Display sh...

Page 7: ... only used on flooded lead acid cells periodically to desulfate the cells This function should not be used on GEL or AGM batteries Version shows version of G3 Display firmware and hardware 3 3 2 Genset menu The Genset function makes it possible to automatically start a Generator when the battery is empty and automatically stops when the battery is full The function requires a Combi in the system t...

Page 8: ...he generator is allowed to run if the combi is unable to fully charge the battery within this time The timer will start to run when the battery voltage is above the voltage trigger level Manual Cont manual control of generator Generator can be controlled manually from trigger voltage until the battery is detected full While battery voltage is below Voltage trigger level it is not possible to stop ...

Page 9: ...G3 Display 006 00001GF User s manual 006 00001DSF rev 002 Clayton Power R D s r o 9 THIS PAGE INTENTIONALLY LEFT BLANK ...

Page 10: ...G3 Display 006 00001GF 10 Clayton Power R D s r o 006 00001DSF rev 003 5 G3 Display outline drawing ...

Page 11: ...kia Phone 421 322 85 00 11 CP International Sales Clayton Power GmbH Oberwolfhauserstrasse 10 8633 Wolfhausen Switzerland Phone 41 55 253 26 00 Fax 41 55 253 26 09 Clayton Power and the Clayton Power logo are trademarks of Clayton Power GmbH All other product or service names are the property of their respective owners Clayton Power R D s r o 2009 All rights reserved Document Number 006 00001DSF r...

Reviews: