background image

2  |   Nord ElEctro 5 UsEr MaNUal os v1.X

CAUTION - ATTENTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

RISQUE DE SHOCK ELECTRIQUE 

NE PAS OUVRIR

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK 

DO NOT REMOVE COVER (OR BACK).

NO USER SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED PERSONNEL.

ATTENTION:POUR EVITER LES RISQUES DE CHOC ELECTRIQUE, NE 

PAS ENLEVER LE COUVERCLE. 

AUCUN ENTRETIEN DE PIECES INTERIEURES PAR L´USAGER. 

CONFIER L´ENTRETIEN AU PERSONNEL QUALIFE.

AVIS: POUR EVITER LES RISQUES D´INCIDENTE OU D´ELECTROCUTION, 

N´EXPOSEZ PAS CET ARTICLE A LA PLUIE OU L´HUMIDITET.

1) Read these instructions.
2) Keep these instructions.
3) Heed all warnings.
4) Follow all instructions.
5) Do not use this apparatus near water.
6) Clean only with dry cloth.
7) Do not block any ventilation openings. Install in accordance 

with the manufacturer’s instructions.
8) Do not install near any heat sources such as radiators, heat 

registers, stoves, or other apparatus (including amplifiers) that 

produce heat.
9) Do not defeat the safety purpose of the polarized or 

grounding-type plug. A polarized plug has two blades with one 

wider than the other. A grounding type plug has two blades 

and a third grounding prong. The wide blade or the third prong 

are provided for your safety. If the provided plug does not fit 

into your outlet, consult an electrician for replacement of the 

obsolete outlet.

10) Protect the power cord from being walked on or pinched 

particularly at plugs, convenience receptacles, and the point 

where they exit from the apparatus.
11) Only use attachments/accessories specified by the manu-

facturer.
12) Use only with the cart, stand, 

tripod, bracket, or table specified by the 

manufacturer, or sold with the apparatus. 

When a cart is used, use caution when 

moving the cart/apparatus combination to 

avoid injury from tip-over.
13) Unplug this apparatus during lightning 

storms or when unused for long periods of time.
14) Refer all servicing to qualified service personnel. Servicing 

is required when the apparatus has been damaged in any way, 

such as power-supply cord or plug is damaged, liquid has been 

spilled or objects have fallen into the apparatus, the apparatus 

has been exposed to rain or moisture, does not operate nor-

mally, or has been dropped.

The lightning flash with the arrowhead symbol within 

an equilateral triangle is intended to alert the user to the 

presence of uninsulated voltage within the products en-

closure that may be of sufficient magnitude to constitute 

a risk of electric shock to persons.

Le symbole éclair avec le point de flèche à l´intérieur d´un triangle 

équilatéral est utilisé pour alerter l´utilisateur de la presence à 

l´intérieur du coffret de ”voltage dangereux” non isolé d´ampleur 
suffisante pour constituer un risque d`éléctrocution.

The exclamation mark within an equilateral triangle is 

intended to alert the user to the presence of important 

operating and maintenance (servicing) instructions in the 

literature accompanying the product.

Le point d´exclamation à l´intérieur d´un triangle équilatéral est 

employé pour alerter l´utilisateur de la présence d´instructions 

importantes pour le fonctionnement et l´entretien (service) dans le 

livret d´instructions accompagnant l´appareil.

Instructions pertaining to a risk of fire, electric shock or injury to persons.

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

Trademarks: 

The Nord logo is a trademark of Clavia DMI AB. All other trademarks 

mentioned in this publication are the properties of their respective holders.
Specifications and appearances are subject to change without notice.  

 

 

 

 

 

Copyright © Clavia DMI AB

No naked flame sources, such as lighted candles, should be placed on 

the apparatus;
Do not use the apparatus in tropical climates.

WARNING

: To reduce the risk of fire or electric shock, do not expose 

this apparatus to rain or moisture. 
The apparatus shall not be exposed to dripping or splashing and that 

no objects filled with liquids, such as vases, shall be placed on the 

apparatus.
The maims plug is used as the disconnect device and shall remain 

readily operable.

Il convient de ne pas placer sur l´appareil de sources de flammes nues, 

telles que des bougies allumées;
L´appareil n’est pas destiné á étre utilisé sous un climat tropical.
 

L´appareil ne doit pas étre exposé á des égouttements d´eau ou des 

éclaboussures et de plus qu´aucun objet rempli de liquide tel que des 

vases ne doit étre placé sur l´appareil.
Lorsque la prise du résau d’alimentation est utilisée comme dispositif 

de déconnexion, ce dispositif doit demeuré aisément accessible.

Warning

 - When using electric products, basic precautions should always be followed, including the following:

Additional Safety Information 

Summary of Contents for Nord Electro 5D 61

Page 1: ...Nord Electro 5 User Manual OS v1 X 1 User Manual English Nord Electro 5D 61 Nord Electro 5D 73 Nord Electro 5HP 73 OS Version 1 0x Edition C Part No 50434 Copyright Clavia DMI AB Edition C...

Page 2: ...ped The lightning flash with the arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated voltage within the products en closure that may be of suff...

Page 3: ...DRWB Sync 7 B3 7 Percussion 8 B3 Bass 8 Pipe 8 VX 8 Farf 8 Piano 8 Long Release 8 String Resonance 9 Mono 9 Kbd Touch 9 Nord Piano Library size comparison chart 9 Sample Synth 9 Dynamics 9 Filter Vel...

Page 4: ...ts are made the value of the parameter will also be shown on the large OLED display M M Pressing and holding the SHIFT button while turning any knob will cause that parameter s current value to be dis...

Page 5: ...KB SPLIT mode or not designed to always give you access to the entire playable range for both Parts The TRANSPOSE function activated by a single press of the button will allow the keyboard to be trans...

Page 6: ...at the current cursor position Repeat the actions above until the new name is complete When finished press STORE again and the STORE PROGRAM TO screen will show Again use the PROG dial to if you want...

Page 7: ...l organs use notched steel disks TONE WHEELS to produce sine waves generated as a wheel rotates at its designated speed close to a corresponding electromagnetical pick up The generated tone whose pitc...

Page 8: ...represented by the sine and sawtooth waveforms The VX organ has three Vibrato modes to choose from V1 V3 each increasing its rate and inten sity FARF The FARF model is based on another easy to recogni...

Page 9: ...through the available samples In places 99 159 within the list samples are displayed using the numbering A0 F9 New samples can be downloaded from www nordkeyboards com or you could create your own sam...

Page 10: ...ing usable for controlling the dynamic range of a sound The knob controls the DRIVE amount either of the tube distortion or the selected amp model or the compression amount when in COMP mode THE ROTAR...

Page 11: ...e Song as well as the name of the active Program By default the Nord Electro 5 contains ten exam ple Songs showing how you could group Programs based on genre These can of course be replaced or rename...

Page 12: ...Optionally use the DEL function to delete the selected character or INS to insert a blank space at the current cursor position Repeat the actions above until the name of your Song is complete When fi...

Page 13: ...LIST VIEW knob of the Sample Synth section The top part of the display will show the numeric list location of the selected sample To return from List View simply press EXIT and you will be back to yo...

Page 14: ...if you want to use the Nord Electro 5 as part of a layered sound or not SCENARIO 2 NORD ELECTRO 5 SENDING MIDI ON PART UPPER IN KB SPLIT MODE With this setup the upper part of the keyboard can be use...

Page 15: ...are a few different ways in which you could set up the Nord Electro 5 together with a sequencer You could either simply use it as a controller keyboard see Scenario 1 to control software synths in a...

Page 16: ...tly or are sent only via MIDI CHANNEL GLOBAL sets the channel the Nord Electro 5 transmits and responds to Could be set to 1 16 or Off Default is 1 CHANNEL LOWER RECEIVE determines the MIDI channel wh...

Page 17: ...rtual hard drive into your Applications folder OVERVIEW The main area of the Nord Sound Manager is the list view divided into tabs representing the three partitions Piano Samp Lib and Program With in...

Page 18: ...he Sample Synth are downloaded from the Nord Sample Library section of www nordkeyboards com Most of the sounds are downloaded as bundles and come in a zip archive containing individual nsmp files Onc...

Page 19: ...g either your selection or any of the Program banks Select one of the two options and then browse to the folder where the Bun dle should be stored In order to transfer a Bundle to the Nord Electro 5 s...

Page 20: ...nnection will send MIDI data to devices such as exter nal sound modules or computers USB CONNECTION The USB port is used for connecting your Nord Electro 5 to a computer The connection can be used for...

Page 21: ...wbar 5 20 Organ Drawbar 6 21 Organ Drawbar 7 22 Organ Drawbar 8 23 Organ Drawbar 9 24 Organ Drawbar Live 25 Organ Percussion Enable 87 Organ Percussion Speed 88 Organ Percussion Level 89 Organ Percuss...

Page 22: ...16 MIDI Out 20 MIDI Upper Receive 15 Model Display 8 Monitor In 20 Mono 9 N Ne5pb file format 19 Ne5p file format 19 Nord Piano Library 17 Nord Sample Library 18 Nord Sound Manager 17 Npno file format...

Page 23: ...ource of interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the follo...

Page 24: ......