10 - Ctrl Pedal Mode
A connected control pedal can be used to control several things . It can
be used as a solitary organ swell pedal (swell is a combination of vol-
ume and frequency control), as a combined organ swell/volume pedal
for the samples type, and finally as a swell/volume pedal for all the
instrument sections (incl . the pianos) in the Nord Electro 4 HP/SW .
Range: O – Organ swell (default), S – Organ swell/sample volume,
P - Organ swell/sample and piano volume
M
A connected control pedal will always be active if the P-Wa or the
RM effect is activated, regardless of the Ctrl Pedal Mode setting.
11 - Organ Trig Mode (Nord Electro 4 SW only)
This allows you to change how the Nord Electro 4 SW keyboard trig-
gers the organ sounds . When “High” is selected, you will trigger the
organ sounds before the key reaches the end of its travel . This mode
closely mimics the way a vintage tonewheel organ trigger its notes .
Range: Hi - High trig (default), Lo - Low trig
High trigger point
Low trigger point
12 - Drawbar Speed
This sets the speed with which the drawbars will increase or decrease
the values when the drawbar buttons are held down .
Range: F- Fast, S- slow
MIDI Menu
1 - Local Control
This allows you to set if the Nord Electro 4 HP/SW keyboard and front
panel controls should control internal Programs or only send note and
controller messages via MIDI . Local On is the normal “mode” . In Local
Off mode, the front panel and keyboard action are transmitted via MIDI
only and does not control the internal sound(s) directly .
Range: On (default), Off
M
Local defaults back to mode On every time the Nord Electro 4 HP/
SW is powered on.
2 - MIDI Interface
Use this setting to choose if you want to use the MIDI interface on the
DIN connectors or the USB-MIDI functionality .
Range: P - DIN MIDI ports, U USB-MIDI (default)
3 - MIDI Channel
This sets the MIDI Channel that the Nord Electro 4 HP/SW transmits
and responds to .
Range: 1-16, OF - off (default = 1)
4 - Lower Channel
This sets the MIDI channel that the Lower Manual of the Nord Electro
4 HP/SW organ section responds to when the organ split and the MIDI
split modes are active .
Range: 1-16, OF - off (default = 2)
5 - Control Change (CC) Mode
This setting specifies how the front panel’s knobs and buttons are han-
dled in the MIDI communication with MIDI Control Change messages .
You can select if the panel controls and functions should either send or
receive, or both, or if Control Change messages should be ignored .
Range: Sr (send & receive - default), r (receive only), S (send only),
Off
6 - Program Change Mode
Specifies how the Nord Electro 4 HP/SW should handle MIDI Program
Change messages .
Range: Sr (send & receive - default), r (receive only), S (send only),
Off
7 - MIDI Split Mode
If MIDI Split mode is On and the Organ is set to a split operation, the
lower manual will be exclusively controlled via incoming MIDI informa-
tion to the Electro 4 HP/SW’s MIDI input . If you connect an external
MIDI keyboard, the Electro 4 HP/SW can then be used in a dual manual
fashion .
Range: On, Off (default)
8 - Dump One
This allows you to perform a MIDI SysEx dump of the currently selected
Program . Press the Store button to perform the dump .
9 - Dump All
This allows you to perform a MIDI SysEx dump of all the Programs in
the Electro 4 HP/SW . Press the Store button to perform the dump .
In the MIDI chapter, on “Receive MIDI SysEx dumps” on page 22, there is
a description on how the Electro 4 HP/SW receives a Sys Ex dump .
10 - Send CC
You can perform a dump of all the active Program’s parameters as
MIDI Control Change messages . Press the Store button to perform the
dump .
18 | Nord ElEctro 4 HP/SW USEr MaNUal oS v1.1x