17/EN
DANGER:
Do not use open flame or do not smoke.
Do not operate any electrical buttons (e.g.
lamp button, door bell and etc.)
Do not use fixed or mobile phones.
Risk of explosion and toxication!
DANGER:
The gas hose must not be clamped, bent or
trapped or come into contact with hot parts of
the product.
There is the risk of explosion due to damaged
gas hose.
•
Push the product towards the kitchen wall.
•
Adjusting the feet of oven
Adjusting the feet of oven
Adjusting the feet of oven
Adjusting the feet of oven
Vibrations during use may cause cooking vessels
to move. This dangerous situation can be
avoided if the product is level and balanced.
For your own safety please ensure the product is
level by adjusting the four feet at the bottom by
turning left or right and align level with the work
top.
Final check
1. Check electrical functions.
2. Open gas supply.
3. Check gas installations for secure fitting and
tightness.
4. Ignite burners and check appearance of the flame.
Flame must be blue and have a regular shape.
If the flame is yellowish, check if the burner
cap is seated securely or clean the burner.
Gas conversion
DANGER:
Before starting any work on the gas
installation, disconnect the gas supply.
There is the risk of explosion!
In order to change your appliance's gas type, change
all injectors and make flame adjustment for all valves
at reduced flow rate position.
Exchange of injector for the burners
1. Take off burner cap and burner body.
2. Unscrew injectors by turning the counter-
clockwise.
3. Fit new injectors.
4. Check all connections for secure fitting and
tightness.
New injectors have their position marked
on their packing or injector table on
Injector table, page 13
can be referred to.
1
Flame failure device (model dependant)
2
Spark plug
3
Injector
4
Burner
Unless there is an abnormal condition, do not
attempt to remove the gas burner taps. You
must call an Authorised service agent if it is
necessary to change the taps.
Reduced gas flow rate setting for hob taps
1. Ignite the burner that is to be adjusted and turn
the knob to the reduced position.
2. Remove the knob from the gas tap.
3. Use an appropriately sized screwdriver to adjust
the flow rate adjustment screw.
For LPG (Butane - Propane) turn the screw clockwise.
For the natural gas, you should turn the screw
counter
counter
counter
counter----clockwise
clockwise
clockwise
clockwiseonce.
»
The normal length of a straight flame in the reduced
position should be 6-7 mm.
4. If the flame is higher than the desired position,
turn the screw clockwise. If it is smaller turn
anticlockwise.
5. For the last control, bring the burner both to high-
flame and reduced positions and check whether
the flame is on or off.
Depending on the type of gas tap used in your
appliance the adjustment screw position may vary.
1
Flow rate adjustment screw
Summary of Contents for CLFG67SS
Page 29: ...29 EN...