45
Suomi
Sähkötekniset tiedot
DC Voltage
Range
Resolution
Accuracy
Overload protection
200 mV
100 μV
± (0,5 % + 2)
250 V DC or AC
2000 mV
1 mV
20 V
10 mV
200 V
100 mV
250 V
1 V
± (0,8 % + 2)
AC Voltage
Range
Resolution
Accuracy
Overload protection
200 V
100 mV
± (1,2 % + 3)
250 V DC or AC
250 V
1 V
DC Current
Range
Resolution
Accuracy
Overload protection
200 μA
0,1 μA
-----------
200 mA 250 V, F (fast), 5 × 20 mm
2000 μA
1 μA
± (1 % + 2)
200 mA 250 V, F (fast), 5 × 20 mm
20 mA
10 μA
± (1 % + 2)
200 mA 250 V, F (fast), 5 × 20 mm
200 mA
100 μA
± (1,2 % + 2)
200 mA 250 V, F (fast), 5 × 20 mm
10 A
10 mA
± (2 % + 5)
10 A, 600 V, F (fast), 6 × 25 mm
Remark:
At 10 A range: For continuous measurement ≤ 10 seconds and interval not
less than 15 minutes.
Resistance
Range
Resolution
Accuracy
Overload protection
200 Ω
0,1 Ω
± (0,8 % + 5)
250 V DC or AC
2000 Ω
1 Ω
± (0,8 % + 2)
20 kΩ
10 Ω
± (0,8 % + 2)
200 kΩ
100 Ω
± (0,8 % + 2)
20 MΩ
10 kΩ
± (1 % + 5)
200 MΩ
100 kΩ
± (5 % (reading -10) + 10)