Air compressors used with the tool must comply with the appropriate 
European Community Safety Directives.

A build-up of moisture or oil in the air compressor will accelerate wear and 
corrosion in the tool. ensure any moisture is drained from the compressor daily 
and the inlet filter is kept clean.

If an unusually long air hose is required, (over 8 metres), the line pressure or the 
hose inside diameter may need to be increased. The air hose must be rated at 
least 150% of the maximum operating pressure of the air tool.

Never exceed the maximum operating pressure for the tool. It is 
recommended that air pressure to this tool does not exceed 90 psi at the tool 
when running. Higher pressures and unclean air will shorten the life of the tool 
due to faster wear and is a possible safety hazard.

BEFORE USE

NOTE: 

Ensure the compressor is turned off.

1. Remove the plastic blanking plug from the air inlet connection.

2. Pour 2-3 drops of airline oil into the oil filling port. This should be done 

regardless of whether or not a lubricated air supply is to be used.

3. If required, connect an in-line mini oiler to the tool.

• A mini oiler helps to prolong the life of any air tool.

4. Connect a suitable hose as shown 

or use the snap connector 
supplied to connect directly to the 
hose.

5. Connect the other end of the hose 

to the compressor.

• PTFE tape may be useful for 

sealing threaded connections.

6. Turn on the air supply and check 

for air leaks. Rectify any found 
before proceeding.

7. If using a mini oiler, place a sheet of paper next the exhaust port and hold 

the throttle open for approximately 30 seconds. The oil volume is correctly 

WARNING: COMPRESSED AIR CAN BE DANGEROUS. ENSURE THAT YOU 
ARE FAMILIAR WITH ALL PRECAUTIONS RELATING TO THE USE OF AIR 
COMPRESSORS AND COMPRESSED AIR SUPPLY.

Summary of Contents for X-Pro CAT201

Page 1: ...OPERATING MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC1119 ISS 1 DIE GRINDER KIT MODEL NO CAT201 PART NO 3120518...

Page 2: ...safe place for future reference SPECIFICATIONS Please note that the details and specifications contained herein are correct at the time of going to print However CLARKE International reserve the right...

Page 3: ...d the side 3 ALWAYS wear ear protectors when using the air tool 4 DO NOT overreach Keep proper footing and balance at all times 5 NEVER use oxygen CO2 combustible gases or any type of bottled gas as a...

Page 4: ...plings should not be located at the air tool They add weight and could fail due to vibration 18 DO NOT force or misuse the air tool It will do a better and safer job at the rate for which it was desig...

Page 5: ...rst time check that all the items are present Any damage or deficiency should be reported to your CLARKE dealer immediately NO DESCRIPTION NO DESCRIPTION A 2 x Collet wrenches 11mm 17mm D Grinding sto...

Page 6: ...ulator is used it will keep the tool in good condition but should be regularly checked and topped up with oil SAE 10 oil should be used and the lubricator adjusted to approx 2 drops per minute Use onl...

Page 7: ...ol due to faster wear and is a possible safety hazard BEFORE USE NOTE Ensure the compressor is turned off 1 Remove the plastic blanking plug from the air inlet connection 2 Pour 2 3 drops of airline o...

Page 8: ...be used undo the screw cap completely and pull out the collet from the collet holder Replace it with the new collet and screw the cap loosely back on FITTING THE GRINDING STONE IMPORTANT Never use chi...

Page 9: ...de the throttle locking lever forward while squeezing the trigger against the tool body 2 Do not use pressure on the stone as this will shorten its life 3 Release the trigger to stop the grinder The t...

Page 10: ...n or sticking mechanism due to lack of lubricant 1 Reduce the force applied to the tool 2 Return to CLARKE dealer for repair 3 Drip air tool lubricating oil into air inlet Allow oil to soak moving par...

Page 11: ...r inlet screen filter for blockage and clean if necessary CLEANING 1 Grit or gum deposits inside an air tool may reduce its efficiency 2 After extensive use remove the inlet screen filter and flush ou...

Page 12: ...of incorrect size or poor condition which will reduce the air supply Your air tool has been designed to give long trouble free service If however having followed the instructions in this booklet care...

Page 13: ...13 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Page 14: ...14 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com COMPONENT PARTS...

Page 15: ...ed to their place of purchase no product can be returned to us without prior permission This guarantee does not affect your statutory rights No Description No Description 1 Main Housing 21 O ring 2 Ho...

Page 16: ......

Reviews: