8
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
If one of the mandrells is required, the
adaptor must be fitted instead of the
pressure cap. Secure the adaptor by
tightening the grub screw with a
suitable hex key as previous.
Select your mandrell depending
upon the size of the workpiece
bearing surface.
The mandrell can then be pushed
into the adaptor where the built-in
spring clip will hold it in place.
Store the mandrells in their positions
on the mounting bracket when not in
use.
OPERATION
1. Place the workpiece on the bed. It must be completely stable and
supported by packing or shims where required. Steel pressing plates are
supplied, which locate on the bed. Place the workpiece on a combination
of these to give it stability.
NOTE:
Any packing pieces or shims used MUST be capable of
withstanding the pressure that will be brought to bear, and MUST
be of sufficient size with sufficient surface area, so as to avoid the
possibility of slipping or springing out. Mating surfaces MUST be
horizontal so that the force being exerted will NOT be at an angle.
CAUTION: DO NOT POINT LOAD THESE ACCESSORIES AS THEY ARE NOT
DESIGNED TO TAKE THE FULL FORCE OF THE RAM IN ONE SPOT. ENSURE
THEY ARE ADEQUATELY SUPPORTED.
Summary of Contents for STRONG-ARM CSA12F