7. Unfasten the protective hose cap
and screw the hose onto the
threaded connection of the
hydraulic ram.
• We recommend sealing the thread
with PTFE tape. Take care not to let
any oil escape while connecting
the hose.
8. Unscrew the filler plug on the end
of the cylinder and check that oil
can be seen at the bottom of the
aperture. Top up if necessary.
9. Screw the pump handle into the
pump actuating lever.
PURGING THE SYSTEM
1. Before using the press, purge any
air from the system by opening
the release valve (turning it anti-
clockwise) and pumping several
full strokes to eliminate any air
bubbles.
2. Close the release valve.
FITTING THE RAM EXTENSIONS
1. Fit the ram extensions and
pressure cap as required.
2. Check all parts are secure and
correctly aligned before using the
press.
The press is now ready for use.