16
All components are now correctly assembled, and the welder
may now be prepared for use as follows:
The Welding Shield
1.
Remove the shield, handle and screws bag from the packaging.
2.
Carefully bend the side and upper panels ‘inwards’ so that the holes in the
upper
panel and top of the side panels coincide (A). Secure together with screws and nuts
provided.
3.
Prise back the window flap and insert the clear glass first, followed by the dark glass,
ensuring they fit snugly in the recesses, then secure the flap with two screws with nuts
provided.
IMPORTANT: The clear glass MUST installed BEFORE the dark glass.
It is important to pay attention to the notes on welding shield maintenance, given on page 25.
When replacing the glass panels, always use parts supplied by Clarke International. The dark
panel is a certified, specific optical class, and should not be exchanged for any other type.
The clear glass panel should be replaced when it becomes badly pitted.
WARNING:
NEVER look at an electric arc without eye protection as this can injure the
eyes permanently. ALWAYS use a protection mask or welding helmet.
Fig.3
NOTE: The correct shade of glass should be used in accordance with the following
chart: