![Clarke MA50 15B Service Manual Download Page 76](http://html1.mh-extra.com/html/clarke/ma50-15b/ma50-15b_service-manual_2614817076.webp)
Solution System
75
Service Manual – MA50 15B
10. Remove the (4) Phillips screws that hold the PCB to the metal case. NOTE: There are nylon washers on the
top and bottom of the PCB. Do not lose these washers
11. When re-installing the control PCB, use a dab of grease to hold the nylon washers in place on the mounting
studs. It is very important to use these nylon washers to prevent a short circuit
12. Re-mount the control PCB to the case using the (4) screws and nylon washers. Again, it is very important to
use the nylon washers to prevent a short circuit
13. Re-attach the wires and connectors to the control PCB. Connect the motor wires from left to right, in the
following manner;
•
Vacuum motor - BLACK wire 2
•
Vacuum motor - RED wire 2
• Brush motor - RED wire 1
• Brush motor - BLACK wire 1
14.
Re-assemble the handle in the reverse order as described above
Summary of Contents for MA50 15B
Page 2: ...Clarke MA50 15B 03 2016 Form No 56043172 Service Manual Model Numbers Clarke MA50 15B English...
Page 15: ...Control System 14 Service Manual MA50 15B Solution Control Valve Solution Solenoid...
Page 21: ...Electrical System 20 Service Manual MA50 15B Wiring Harness Diagram BR 12 17A 17A...
Page 48: ...Recovery System 47 Service Manual MA50 15B Vacuum Hose Pick Up Tube Adapter Vacuum seals x 2...
Page 69: ...Solution System 68 Service Manual MA50 15B Solution Valve Solenoid Solution Switch...
Page 78: ...Squeegee System 77 Service Manual MA50 15B Squeegee Assembly Squeegee Thumb Screws...
Page 79: ...Squeegee System 78 Service Manual MA50 15B Squeegee Lift Handle Squeegee Lift Cable...