![Clarke MA50 15B Service Manual Download Page 53](http://html1.mh-extra.com/html/clarke/ma50-15b/ma50-15b_service-manual_2614817053.webp)
Recovery System
52
Service Manual – MA50 15B
13.
Remove the (2) plastic tie down brackets that hold the vacuum motor to the metal deck plate
14. Remove the sound reducing foam from the defective vacuum motor
15. Remove the defective vacuum motor from the machine
Installation:
1. Wrap the sound reducing foam around the replacement vacuum motor
2. Install the vacuum motor onto the machine, insuring that the round opening in the vacuum motor is oriented
onto the flange and “O” ring
3.
Re-attach the (2) plastic tie down brackets
4.
Re-connect the wire connector, and zip tie as required
5.
Re-asemble the machine in the reverse order
Summary of Contents for MA50 15B
Page 2: ...Clarke MA50 15B 03 2016 Form No 56043172 Service Manual Model Numbers Clarke MA50 15B English...
Page 15: ...Control System 14 Service Manual MA50 15B Solution Control Valve Solution Solenoid...
Page 21: ...Electrical System 20 Service Manual MA50 15B Wiring Harness Diagram BR 12 17A 17A...
Page 48: ...Recovery System 47 Service Manual MA50 15B Vacuum Hose Pick Up Tube Adapter Vacuum seals x 2...
Page 69: ...Solution System 68 Service Manual MA50 15B Solution Valve Solenoid Solution Switch...
Page 78: ...Squeegee System 77 Service Manual MA50 15B Squeegee Assembly Squeegee Thumb Screws...
Page 79: ...Squeegee System 78 Service Manual MA50 15B Squeegee Lift Handle Squeegee Lift Cable...