background image

Electronic  Service

Manuals

This electronic document is provided as a service to our customers.
We do not create the contents of the information contained in this docu-
ment.  Should you have detailed questions pertaining to the information
contained in this document, you may contact Michco, or the manufac-
turer which provided the original information in this electronic deliver-
able.  Michco’s only part in this electronic deliverable was the electronic
assembly process.  By providing this manual on line we are not guaran-
teeing parts availability.

You may contact Michco through the following methods:

Phone (517) 484-9312 or (800) 331-3339

2011 N. High St.  -- Lansing, Michigan -- 48906

Fax: (517) 484-9836

Email: [email protected]

Web site: www.Michco.Com

Parts Web site:  www.FloorMachineParts.Com

Order Parts on Line at:

www.FloorMachineParts.Com

Directly to Parts & Service:

By Email: 

[email protected]

By Fax: (517) 702-2041

By Voice: Use numbers above.

Serving the Cleaning Industry Since 1922

Notice: All copyrighted material remains property of original owners, all trademarks are property of respective owners.
Manuals are subject to Manufacturer’s reproduction limitations.  Originals or reproductions were provided by manufacturers
through a request.  We make no warranty as to the correctness of information provided in this document and you assume
all risk.  By placing these manuals on line we are not declaring our corporation to be an manufacturer authorized dealer or
provider, please check our web site for authorized manufacturers we represent.

Summary of Contents for MA50 15B

Page 1: ...an 48906 Fax 517 484 9836 Email CustServe Michco com Web site www Michco Com Parts Web site www FloorMachineParts Com Order Parts on Line at www FloorMachineParts Com Directly to Parts Service By Emai...

Page 2: ...Clarke MA50 15B 03 2016 Form No 56043172 Service Manual Model Numbers Clarke MA50 15B English...

Page 3: ...12 Functional Description 12 Component Locations 12 Maintenance and Adjustment 16 Electrical System 17 Functional Description 17 Component Locations 18 Wiring Harness Diagram 20 Battery Connections 21...

Page 4: ...ubleshooting 60 Removal and Installation 60 Drive Belt 60 Brush Motor 61 Shop Measurements 65 Solution System 66 Functional Description 66 Circuit Description 66 Component Locations 67 Maintenance and...

Page 5: ...charger is required Service Manual Purpose The service manual is a resource for professional service technicians It provides information for understanding how the machine operates where components ar...

Page 6: ...le for any resulting accidents Machine Lifting The Clarke MA50 15B weighs 124 pounds with the batteries installed Use 2 people to lift and or carry the machine The Clarke MA50 15B should not be lifted...

Page 7: ...5 Gallons 13 5 Liters Brush Pad Pressure 44 5 Pounds 20 Kg Squeegee 20 Inches 51 Cm Drive System Pad Assist Pad Assist Brush Motor RPM Speed 1 3 H P 150 RPM 25Kw 150 RPM Vacuum Motor Waterlift 1 3 H...

Page 8: ...General Information 7 Service Manual MA50 15B Component Locations Recovery Tank Recovery Tank Lid Brush Deck Solution Fill Hole Solution Tank ON OFF switch Brush switch Vacuum switch Solution switch...

Page 9: ...General Information 8 Service Manual MA50 15B Solution Control Valve Squeegee Assembly Brush Solution Tank Drain Cap Recovery Tank Drain cap...

Page 10: ...General Information 9 Service Manual MA50 15B Operating Triggers Handle Adjust Lever Squeegee Lift Handle Squeegee Lift Cable...

Page 11: ...queegee assembly and wipe it down with a damp cloth X Remove the float shut off and rinse thoroughly X Clean off the machine with a damp towel X Check batteries for loose or corroded connections X Che...

Page 12: ...s standard with a medium duty brush An optional pad driver can be ordered through your Nilfisk dealer Squeegee Blades The Clarke MA50 15B comes standard with neoprene rubber squeegee blades Optional p...

Page 13: ...re to the vacuum and brush motors the solution valve the on board charger and the indicator LED s on the switch panel The solution flow is controlled by a manually adjusted valve The Vacuum motor and...

Page 14: ...Control System 13 Service Manual MA50 15B Triggers Viewed inside control housing Triggers Trigger switch...

Page 15: ...Control System 14 Service Manual MA50 15B Solution Control Valve Solution Solenoid...

Page 16: ...ystem 15 Service Manual MA50 15B Shown with Handle removed from machine and cover removed from Circuit box On Board Charger Control PCB Circuit Breakers On Board Charger Plug On Board Charger Indicato...

Page 17: ...Control System 16 Service Manual MA50 15B Maintenance and Adjustment No maintenance or adjustment is required for the control system...

Page 18: ...t of 5 amps maximum The electrical system is powered by 2 12 volt batteries for a total of 24 volts Heavy wires connect the batteries in series The battery charger has an interlock to prevent charging...

Page 19: ...Manual MA50 15B Component Locations Batteries Battery Connector Switch panel Circuit Breakers Charger plug and LED s Charger Control PCB 2 12 volt batteries wired in series Battery Connector Switch P...

Page 20: ...Electrical System 19 Service Manual MA50 15B On Board Charger Control PCB On Board Charger Plug On Board Charger LED Indicator lights Circuit Breakers...

Page 21: ...Electrical System 20 Service Manual MA50 15B Wiring Harness Diagram BR 12 17A 17A...

Page 22: ...ace the machine near an electrical outlet The use of an extension cord is not recommended 3 Plug the charger power cord into the machine plug socket is on the rear of the machine 4 Plug the other end...

Page 23: ...ttery performance or longevity If the batteries are fully dis charged it will take 10 12 hours to fully re charge them Insure the charger is not plugged in to an outlet that may be switched off when t...

Page 24: ...Electrical System 23 Service Manual MA50 15B 7 Lift and tilt the handle away from the machine 8 Remove the 2 Phillips screws that hold the charger in...

Page 25: ...he charger indiscator LED lights align with the holes in the metal cover of the machine 11 Re assemble in the reverse order Control PCB 1 Gain access to the the control PCB following the steps listed...

Page 26: ...t is very important to use these nylon washers to prevent a short circuit 5 Re mount the control PCB to the case using the 4 screws and nylon washers Again it is very important to use the nylon washer...

Page 27: ...motor Defective Control PCB Replace Control PCB Defective Switch PCB Replace Switch PCB Defective trigger switch Replace trigger switch Solution solenoid does not open Defective Solution solenoid Repl...

Page 28: ...condition above not met 0 volts DC Figure 2 Showing the Solution solenoid connector on the Control PCB Measurement Point Conditions Volts DC Reading DVM Black GND probe on B DVM Red probe on Blue con...

Page 29: ...th DVM Ground Black probe on B and Red probe with T pin with connector plugged into Control PCB Communication Wire Voltage Reading Notes RED 5V 5 volts DC always DC Supply to Switch PCB VIOLET Pin 2 C...

Page 30: ...e is the Squeegee lift lever mechanism This lever raises and lowers the squeegee assembly At the bottom of the handle system is the metal enclosure Circuit Box that houses the control PCB and on board...

Page 31: ...30 Service Manual MA50 15B Handle System Switch panel PCB behind label Switch PCB Switch label Operating Triggers Handle Adjust Lever Front Handle Cover...

Page 32: ...31 Service Manual MA50 15B Handle System Squeegee Lift Lever Squeegee Cable Handle Pivot Point Circuit Box Circuit Breakers...

Page 33: ...32 Service Manual MA50 15B Handle System Control PCB On board Battery Charger The circuit box cover was removed to show the location of these parts Communication cable At switch PCB At control PCB...

Page 34: ...n both tanks completely 2 Remove the Recovery Tank 3 Disconnect the batteries 4 Remove the batteries as a pack 5 Fold the handle down over the machine 6 Remove the 8 screws that hold the rear cover to...

Page 35: ...e rear switch cover 10 Disconnect the wire connectors from the switch PCB 11 The rear cover assembly is now free 12 Remove the switch label to access the 4 screws that attach the switch PCB to the hou...

Page 36: ...le to the machine Triggers and Trigger Switch 1 Drain both tanks completely 2 Remove the Recovery Tank 3 Disconnect the batteries 4 Remove the batteries as a pack 5 Fold the handle down over the machi...

Page 37: ...y is now free 12 Remove the 2 screws that attach the trigger switch to the handle cover 13 Remove the wire harness from the defective switch and attach the wires to the new switch to the same terminal...

Page 38: ...outed under the triggers between the plastic housing and the triggers in order for the handle cover assembly to be re assembled properly 16 Re assemble the handle covers Handle Adjust Cable and Gears...

Page 39: ...andle adjust cable and slide it out of the groove of the handle bar 10 Now you must remove the handle from the machine to access the other end of the cable Remove the recovery tank Disconnect batterie...

Page 40: ...39 Service Manual MA50 15B Handle System 11 Remove the 2 Phillips screws that secure the cover plate 12 Lift and tilt the handle away from the machine Allen bolts x 6 Phillips Screws x 2...

Page 41: ...at hold the charger in 14 Disconnect the power and interlock wires 15 Remove the charger from the circuit box 16 Remove the 4 Allen head screws that hold the left guide block to the handle Loosen the...

Page 42: ...le System 17 You can now remove the guide block and access the gear spring assembly 18 Remove the entire cable with gears 19 Replace the defective parts with new and apply a small amount of grease to...

Page 43: ...the handle 21 Re connect the cable to the top mount 22 Adjust the top nut so there is about of movement space between the 2 parts 23 Re assemble the gears into the guide blocks and re attach the guid...

Page 44: ...43 Service Manual MA50 15B Handle System 26 You can make small adjustments to the cable by removing the rubber plug on the end of the pivot point...

Page 45: ...portant that the ball float assembly is present and in good working order The vacuum motor will be damaged if water and or foam gets past the ball float Between the solution tank and recovery tank are...

Page 46: ...Recovery System 45 Service Manual MA50 15B Vacuum Seals Recovery Tank Recovery Tank Lid Recovery Tank Latch Vacuum Motor Shown with motor plate out of machine...

Page 47: ...Recovery System 46 Service Manual MA50 15B Vacuum Motor circuit breaker Ball Float Assembly Standpipe Vacuum Switch...

Page 48: ...Recovery System 47 Service Manual MA50 15B Vacuum Hose Pick Up Tube Adapter Vacuum seals x 2...

Page 49: ...tank Clogged or kinked vacuum pick up hose Check and clean out vacuum pick up hose Ball Float is stuck Remove and clean ball float Air Leaks Recovery tank lid is not screwed on tightly Ensure cover is...

Page 50: ...covery system that the squeegee blades are in good condition and have the correct down pressure Adjustment of the squeegee down pressure and instructions for replacing the squeegee blades will be disc...

Page 51: ...move the plastic retaining strips out of the way of the motor wires and squeegee lift cable This will allow you more room for movement 11 For the brush deck mounting bolts Grasp the nylock nut and uns...

Page 52: ...left side bolts NOTE The shorter Allen bolt toward the rear of the machine is used as a stop You can now carefully move the entire brush head out of the way to gain access to the squeegee cable mounti...

Page 53: ...ove the defective vacuum motor from the machine Installation 1 Wrap the sound reducing foam around the replacement vacuum motor 2 Install the vacuum motor onto the machine insuring that the round open...

Page 54: ...2 Remove the 3 screws that hold in the vacuum seals 3 Lift up the plastic strap and you can now slip the vacuum seals off from the hose cuffs and out of the plastic strip 4 Slip the old seals out of...

Page 55: ...cing the switch PCB see the HANDLE SYSTEM section of this manual Control PCB Replacement of the Control PCB is covered in the ELECTRICAL SYSTEM section of this manual Specifications Shop Measurements...

Page 56: ...te if the power switch is ON the brush switch is ON and the operating triggers are engaged Tension on the drive belt is kept constant by a spring loaded tensioner Circuit Description The brush motor r...

Page 57: ...Scrub System 56 Service Manual MA50 15B Power Switch Brush Switch Switch PCB Behind Label Operating Triggers...

Page 58: ...Scrub System 57 Service Manual MA50 15B Brush Circuit Breaker This view is shown with the handle and circuit box cover removed Control PCB...

Page 59: ...Scrub System 58 Service Manual MA50 15B Brush motor This view shown with motor plate removed from machine Driven Pulley Drive Belt...

Page 60: ...Scrub System 59 Service Manual MA50 15B Belt Tension Pulley The Belt Tension Bracket and Spring are located on the opposite side of the driven puley Belt Tension Bracket Belt Tension Spring...

Page 61: ...but the driven pulley spins freely Brush circuit breaker is tripped Reset circuit breaker Defective trigger switch Replace trigger switch see Electrical system Defective brush motor Replace brush moto...

Page 62: ...th side of the belt rides on the Idler and driven pulleys Brush Motor 1 Drain both the Solution and Recovery tanks 2 Remove the recovery tank 3 Remove the batteries as a pack 4 Use the Squeegee lift l...

Page 63: ...ve the plastic retaining strips out of the way of the motor wires and squeegee lift cable This will allow you more room for movement 10 For the brush deck mounting bolts Grasp the nylock nut and unscr...

Page 64: ...the rear of the machine is used as a stop You can now carefully move the entire brush head out of the way to gain access to the brush motor 11 Loosen the belt tension bracket bolt and use a screwdriv...

Page 65: ...he drive belt 13 Remove the large nut that holds the driven pulley 14 Remove the pulley to gain access to the brush motor mounting screws 15 Remove the 4 brush motor mounting screws You will have to s...

Page 66: ...sh motor connector 17 Install the new brush motor in the reverse order Shop Measurements Amp draw of brush motor free spin 2 8 amps Amp draw of brush motor with brush turning on floor 9 5 amps Voltage...

Page 67: ...N position the brush switch is in the ON position and the safety trigger switch is engaged Once the solution valve is open the solution continues to a tube that feeds the solution to an elbow just abo...

Page 68: ...Solution System 67 Service Manual MA50 15B Component Locations Solution Tank Solution Shut off Adjustment Valve Solution Valve solenoid Solution Switch Solution Tank Solution Adjust Shut off Valve...

Page 69: ...Solution System 68 Service Manual MA50 15B Solution Valve Solenoid Solution Switch...

Page 70: ...roblem Cause Correction No Solution Flow Solution switch not in ON position Turn Solution switch to the ON position Solution switch is defective Replace switch panel Solution Solenoid is defective Rep...

Page 71: ...nk 3 Remove the batteries as a pack and set out of the way 4 Tip the machine back and remove the squeegee assembly and brush 5 GENTLY tip the machine onto it s side 6 Remove the 2 screws that attach t...

Page 72: ...le to the machine and 2 Phillips screws that hold the circuit box cover on Do not remove the handle from the machine After the 2 cover screws are removed put 2 of the Allen bolts with acorn nuts back...

Page 73: ...back on it s side and re install the new solution solenoid Solution Flow control valve 1 Drain both tanks 2 Tip the machine back to gain access to the solution control valve 3 The larger hose barb on...

Page 74: ...eries as a pack 4 Remove 5 of the 6 Allen bolts w acorn nuts NOTE The 2 longer Allen bolts go through the support brackets 5 Before you remove the last bolt fold the handle down over the machine 6 Rem...

Page 75: ...anual MA50 15B 8 Lift and tilt the handle away from the machine 9 Disconnect all of the wires and connectors from the PCB The terminals for the 12 gauge wires from the batteries are screwed to the PCB...

Page 76: ...is very important to use these nylon washers to prevent a short circuit 12 Re mount the control PCB to the case using the 4 screws and nylon washers Again it is very important to use the nylon washer...

Page 77: ...he the squeegee mount bracket The squeegee assembly itself does not have any adjustments The squeegee mounting bracket does have a bolt nut for adjusting the down pressure of the squeegee assembly Com...

Page 78: ...Squeegee System 77 Service Manual MA50 15B Squeegee Assembly Squeegee Thumb Screws...

Page 79: ...Squeegee System 78 Service Manual MA50 15B Squeegee Lift Handle Squeegee Lift Cable...

Page 80: ...the squeegee blade in the proper position for wiping the floor nearly dry Proper deflection is between 1 8 and 1 4 inch 1 Lower the squeegee lift cable using the squeegee lift handle 2 Tip the machin...

Page 81: ...Solution and Recovery tanks 2 Remove the recovery tank 3 Remove the batteries as a pack 4 Use the Squeegee lift lever on the handle to lower the squeegee assembly 5 Tip the machine back 6 Remove the b...

Page 82: ...move the plastic retaining strips out of the way of the motor wires and squeegee lift cable This will allow you more room for movement 11 For the brush deck mounting bolts Grasp the nylock nut and uns...

Page 83: ...bolt toward the rear of the machine is used as a stop You can now carefully move the entire brush head out of the way to gain access to the squeegee cable mounting brackets 12 Slightly loosen the nut...

Page 84: ...Squeegee System 83 Service Manual MA50 15B 13 Remove the 2 plastic clamps that hold the squeegee to the rear of the machine...

Page 85: ...ble out of the machine 16 Replace in reverse order Squeegee Blades 1 Lower the squeegee lift lever on the handle 2 Tip the machine back 3 Remove the squeegee assembly by unscrewing the 2 thumb screws...

Page 86: ...c backing strips NOTE The inside backing strip is shorter than the outside strip 7 You can now remove the squeegee blades NOTE Both squeegee can be flipped and used again The blades have working surfa...

Page 87: ...ck up adapter tube Insure drain plug is installed correctly Check the cover and adjust replace as necessary Restrictions due to build up of debris In the recovery tank or standpipe In the vacuum hose...

Reviews: