ELECTRICAL CONNECTIONS

Connect the mains lead to a standard, 240 volt (50Hz) electrical supply through a

fused good quality (rubber preferred)13 amp BS 1363 plug, or a suitable fused

isolator switch.

WARNING: THIS APPLIANCE MUST BE EARTHED

IMPORTANT: The wires in the mains lead are coloured in accordance with the

following code:

Green & Yellow

-

Earth

Blue

-

Neutral

Brown

-

Live

As the colours of the flexible cord of this appliance may not correspond with the

coloured markings identifying terminals in your plug, proceed as follows:

Connect GREEN & YELLOW cord to terminal marked with a letter “E” or Earth

symbol ‘      ’ or coloured GREEN or GREEN & YELLOW.

Connect BROWN cord to terminal marked letter “L” or coloured RED.

Connect BLUE cord to terminal marked letter “N” or coloured BLACK.

We strongly recommend that this unit is fitted with a Residual Current Device (RCD).

FUSE RATING

The fuse in the plug for this appliance must be rated at 

5 amps.

IMPORTANT NOTICE

If this appliance is fitted with a plug which is moulded onto the electric cable (i.e.

non rewirable) please note:
1. This plug must be thrown away if it is cut from the electric cable.  There is a

danger of electric shock if it is subsequently inserted in a socket outlet.

2. Never use the plug without the fuse cover fitted.
3. Should you wish to replace a detachable fuse carrier, ensure that the correct

re-placement is used (as indicated by marking or colour code).

4. Replacement fuse covers can be obtained from your local dealer, an

electrical stockist, or CLARKE INTERNATIONAL Spare Parts Department

5. The fuse in the plug must be replaced with one of the same rating and this

replacement must be ASTA approved to BS1362.

5

Summary of Contents for CBG6RP

Page 1: ...BENCH GRINDER MODEL CBG6RP OPERATING MAINTENANCE INSTRUCTIONS 0101...

Page 2: ......

Page 3: ...Safety Rules 2 Special Safety Rules for Grinders 3 Pre Assembly Check 4 Electrical Connections Fuse Rating 5 Assembly Eyeshield and Toolrest 6 Maintenance incl changing the grinding wheel 7 Technical...

Page 4: ...d be properly repaired or replaced If in any doubt contact your local dealer ADDITIONAL SAFETY RULES FOR BENCH GRINDERS 1 Replace a cracked wheel immediately 2 Always use guards and eyeshield 3 Do not...

Page 5: ...aler or Clarke International for replacement 1 Main Body A switch and power cable with plug are included 2 Two Eye Shields B each complete with 1 x nut 1 x bolt 1 x spring washer 2 x flat washers 3 Tw...

Page 6: ...marked letter N or coloured BLACK We strongly recommend that this unit is fitted with a Residual Current Device RCD FUSE RATING The fuse in the plug for this appliance must be rated at 5 amps IMPORTAN...

Page 7: ...grinding wheels as possible without impairing the wheels rotation As the wheel wears down with use it will be necessary to re adjust the park Arrester brackets in order to maintain a gap between the...

Page 8: ...HANGING THE GRINDING WHEEL To renew or change the grinding wheels follow the steps given below 1 Switch off and un plug from mains power supply Disassemble outer covers left or right by removing the t...

Page 9: ...Speed 2900 RPM Power Rating 150Watts Wheel Size 150 X 20 X12 7 Mm Fuse Rating 5 Amps Wheels 1 X Fine 1 X Coarse Part No 6500520 Weight Packed 8 kg Duty Cycle 5 5 Min This machine may be operated for...

Page 10: ...T5481919 20 Capacitor HT5481920 21 Screw 3040528 22 Spring Washer 3040582 23 Flat Washer 3044576 24 Tool Rest LH HT6481924 24A Tool Rest RH HT6481924A 25 Screw HT6481925 26 Bearing HT5481926 27 Circli...

Page 11: ...9 PARTS DIAGRAM...

Page 12: ......

Reviews: