21
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
2. Switch on using the switch
located on the rear panel.
3. For Flux or MMA welding, select
the appropriate welding rod and
fit it into the welding rod holder.
The following sizes can be used and are available from your CLARKE dealer.
4. Attach the work clamp to the workpiece as close as possible to the area
being welded. Clean with a wire brush where necessary to ensure the
connection is as clean as possible.
ROD DIAMETER
WORKPIECE THICKNESS
MIG
0.6 mm
1-5 mm
0.8 mm
0.9 mm
1.0 mm
MMA
1.6 mm
1.5 - 2.0 mm
2.5 mm
2.5 - 3.0 mm
3.2 mm
3.5 - 4.5 mm
Summary of Contents for 6015601