SETTING UP INSTRUCTIONS
ATTACHING THE REGULATORS (FIG 1)
Open the oxygen cylinder valve
(arrowed) briefly to blow out any dust
etc, ensure the valve is fully closed
before continuing.
Attach the oxygen regulator (
Blue
)
and tighten the connector using
25mm open ended spanner.
DO NOT
overtighten.
Repeat the above procedure for
attaching the acetylene regulator
(Red).
NOTE:
The acetylene connections are all left handed whilst the oxygen
connections are all right handed.
ATTACHING THE HOSES (FIG 2)
Connect the hoses (complete with
flashback arrestors on each one) to
the regulator outlets, blue to the
oxygen outlet marked
‘OUT’
and red
to the acetylene outlet marked
‘OUT’
,
again observing left and right
handed threads.
Tighten both connectors using a
19mm open ended spanner.
DO NOT
overtighten.
WARNING: ENSURE THERE ARE NO NAKED FLAMES OR SPARKS WHICH
COULD IGNITE WHEN PRIMING OR PURGING THE HOSES ETC. ENSURE A
FIRE EXTINGUISHER IS ALWAYS AT HAND IN CASE OF ACCIDENTS.