14
DRAINING THE RESERVOIR
1. Turn the compressor off and
disconnect from the power
supply.
2. Slowly open one of the outlet
valves to depressureise the tank.
•
You will heara hissing sound as the
tank depressurises.
•
Do not leave the compressor
unattended if the tank is
pressurised
3. Put a container below the drain valve to collect the condensate.
4. Open the drain valve slowly.
• Condensation will drain from the tank.
5. Close the drain valve when the tank has fully drained.
RESET BUTTON
This compressor has a thermal
overload device.
If the motor gets too hot, the thermal
overload device cuts the power
which prevents damage to the motor.
If the thermal overload device
operates, let the motor cool down for
5 minutes and push the reset button.
If you start the compressor and the
overload cutout operates again, stop
the compressor and disconnect from the power supply and have your
compressor examined by a qualified service agent.
CAUTION: YOU MUST DRAIN THE RESERVOIR AFTER EACH DAYS USE AND
BEFORE YOU PUT YOUR COMPRESSOR INTO STORAGE