ELECTRICAL CONNECTIONS

Connect the mains lead to a standard, 230 Volt (50Hz) electrical supply 
through an approved 13 amp BS 1363 plug, or a suitably fused isolator switch.

If the plug has to be changed because it is not suitable for your socket, or 
because of damage, it must be removed and a replacement fitted, following 
the wiring instructions shown below. The old plug must be discarded safely, as 
insertion into a power socket could cause an electrical hazard.

If the colours of the wires in the power cable do not agree with the markings 
on the plug.

• The BLUE wire must be 

connected to the 
terminal which is 
marked N or coloured 
black.

• The BROWN wire must 

be connected to the 
terminal which is 
marked L or coloured 
red.

• The YELLOW AND 

GREEN wire must be 
connected to the terminal which is marked E or 

 or coloured green.

We strongly recommend that this machine is connected to the mains supply 
through a Residual Current Device (RCD)

If you are not sure, consult a qualified electrician. DO NOT try to do any 
repairs. 

WARNING! Read these electrical safety instructions thoroughly 
before connecting the product to the mains supply.

WARNING! The wires in the power cable of this product are 
coloured in accordance with the following code:

Blue = Neutral      Brown = Live     Yellow and Green = Earth

Plug must be BS1363/A approved.

Always fit 

Ensure that the outer sheath of 

Neutral

(Blue)

Live

(Brown)

Earth

(Green and 

a 13 Amp 

the cable is firmly held by the clamp

fuse.

Yellow)

Summary of Contents for 2242010

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS LS1212 24L OIL FREE AIR COMPRESSOR MODEL NO RANGER 6 240 PART NO 2242010...

Page 2: ...om the date of purchase Please keep your receipt which will be required as proof of purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not us...

Page 3: ...r to the recommended setting for the tool 10 When spraying flammable materials e g cellulose paint ensure that there is sufficient airflow and keep clear of any source of ignition 11 Before spraying a...

Page 4: ...connected to the terminal which is marked N or coloured black The BROWN wire must be connected to the terminal which is marked L or coloured red The YELLOW AND GREEN wire must be connected to the term...

Page 5: ...Use a suitable spanner to attach the wheels to the compressor Use the washers and spring washer in the positions shown ATTACH THE SUPPORT FOOT Insert the support foot into the position shown FIT THE...

Page 6: ...OFF position pushed down Make sure that the compressor is on level ground Make sure that the supply voltage matches the voltage shown on the data label MOVING THE AIR COMPRESSOR Stop the compressor a...

Page 7: ...r hose 3 Turn the outlet valve handle to the on position NOTE The outlet valve is shown without the air hose fitted for clarity TURNING THE COMPRESSOR ON 1 Plug the compressor into the power supply 2...

Page 8: ...ent SET THE OUTPUT PRESSURE When viewed from the front the left hand outlet valve is adjustable The right hand outlet valve will only supply the full reservoir pressure and is not adjustable 1 Use the...

Page 9: ...e the air hose 4 Disconnect the tool from the hose TURNING THE COMPRESSOR OFF 1 Follow steps 1 3 in Removing Tools From The Air Hose above 2 Disconnect the compressor from the power supply 3 Slowly op...

Page 10: ...fully drained RESET BUTTON This compressor has a thermal overload device If the motor gets too hot the thermal overload device cuts the power which prevents damage to the motor If the thermal overloa...

Page 11: ...be examined monthly more often in dusty conditions 1 Remove the filter from the compressor 2 Remove the filter cover from the filter 3 Remove the filter from the filter cover 4 Clean the sponge and th...

Page 12: ...or is switched OFF and disconnected from the power supply 2 Examine the non return valve and replace the gasket and valve if necessary SPECIFICATIONS Max Pressure 8 Bar Voltage 230 VAC 50 60Hz Air Dis...

Page 13: ...compressor does not reach the set pressure and overheats easily Compressor head gasket blown or valve broken 1 Return the machine to your nearest service agent Compressor does not start The reservoir...

Page 14: ...14 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com EXPLODED DIAGRAM...

Page 15: ...14 HTRAN624030 31 Fan HTRAN624031 32 Bolt M5 105 HTRAN624032 33 Spring Washer HTRAN624033 34 Screw M4 10 HTRAN624034 35 Spring Washer HTRAN624035 36 Tooth Washer 4 HTRAN624036 37 Screw M3 6 HTRAN62403...

Page 16: ...16 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Page 17: ...17 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Page 18: ...18 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com POPULAR ACCESSORIES...

Page 19: ...19 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com NOTES...

Page 20: ......

Reviews: