6
H1/3 WHITE/BLUE
200 mA (-) channel 3 output
This wire provides a (-) 200 mA output whenever the remote button(s) controlling Channel 3 is pressed.
This output can be programmed to provide the following types of output (see System Features Learn
Routine section of this guide):
➤
➤
A
validity
output will send a signal as long as the transmission is received.
➤
➤
A
latched
output will send a signal continuously when the Channel 3 button(s) is pressed and
released. The signal will continue until channel three is pressed again.
➤
➤
A
latched/reset with ignition
output works similar to the latched output, but will also reset (output
will stop) when the ignition is turned on and then off.
➤
➤
A
30 second timed
output will send a signal for 30 seconds when channel three is pressed. This
output can be shut off during the 30-second period by pressing Channel 3 again.
➤
➤
This output can also be programmed to provide a
second unlock pulse
when the unlock button is
pressed a second time after disarming the system. This can be used to unlock the passenger doors
when installing progressive door locks.
H1/4 BLACK/WHITE
high current output from on-board domelight supervision relay
Connect this wire directly to the domelight circuit in the vehicle. The on-board relay will drive circuits
up to 20 amperes. The polarity of this output is determined by the connection of the input wire H2/B
in the Relay Harness.
N
NO
OTTEE:: If the input wire H2/B is not connected, there will be no output on this wire.
H1/5 GREEN
(-) door trigger input
Most vehicles use negative door trigger circuits. Connect the green wire to a wire showing ground when
any door is opened. When connecting to newer model vehicles there is generally a need to use individ-
ual door triggers. This wire will report Zone 3.
N
NO
OTTEE:: If using a door trigger wire that has a delay, Advanced Menu 2, feature 6, or the Pro Security
Programmer can be used to turn open zone notification off.
IIM
MPPO
ORRTTA
AN
NTT!! Never use this wire to drive anything but a relay or a low-current input! This
transistorized output can only supply 200 mA, and connecting directly to a solenoid, motor,
or other high-current device will cause the module to fail.
Summary of Contents for S400
Page 13: ...14 ...
Page 18: ...19 type G door lock system wiring diagram ...
Page 36: ...37 wiring quick reference guide ...
Page 37: ...38 ...