3.1.3 Security options
When RS232/RS485 is used for communication of device and PC, it is necessary to set
device ID. Device ID: 1—254. If RS232/RS485 is used, this ID needs to be input on the
software communication interface. To improve the security of attendance data,
connection password needs to be set here. Connection password must be input when
PC software is to connect device to read data. Connection password: System password
is 0 by default. Namely, there is no password.
)
it can be set as other value. After
setting, the password must be input if software is to communicate with device. Or the
connection will fail. The password length is 1
~
6 digits.
3.1.4 Wiegand
Define Wiegand input & output format.
3.1.4.1 Input Opt.
User defined format: User defined Wiegand input format bit digit: Wiegand
data digit length pulse width: Pulse width is 100 microseconds by default, which
can be adjusted from 20 to 800. Pulse interval: It is 900 microseconds by
default, which can adjusted between 200 and 20000. Input content: Content
contained in Wiegand input signal, including User ID or card number.