Nitrogen Generators
Nitro35 Nitro70
13
e
During the first start-up, the Nitrogen reservoir will be full of air: the final purity
will be reached only when the total volume of air will be purged with the Nitrogen
fluxed by the generator. The requested time for this operation depends from the
model of the generator, from the requested purity of the Nitrogen as well as
from the volume of the reservoir itself.
CONNECTION
• Locate Nitrogen connection, that is indicated by the script NITROGEN on the
back of the generator;
• take the fitting (1), and mount it;
• connect the line.
e
We recommend to insert an on-off valve on the flow on the outlet line.
4.3.2.
Air inlet
The specification the inlet compressed air are very important for the performan-
ce and for the working life of the Nitrogen generator.
In addition to the minimum requirement of pressure and flow rate (specific of
the model of the generator), compressed air must comply to following specifica-
tion:
(ISO 8573-1; class 1-4-1):
Dew Point< 3° C
Max. oil content:< 0,01 mg/m
3
Max. particulate concentration (0,1
µ
m diameter)< 0.1 mg/m
3
e
In case of utilization of a poor quality air, permanent damages to the generator
can occur. In this case, Claind won’t be liable for the damages and the costs of
the possible reparation will be charged to the Customer.
e
Puirty of produced Nitrogen decreases as the pressure of the compressd air de-
creases. It is highly recommended to install a reservoir in case that the line isn’t
adequately dimensioned. In case of any need of clarification, please do not he-
sitate to contact CLAIND for other suggestion on the kind of compressed air
plant (compressor, dryer, filters and reservoir) adequate for the specific applica-
tion.
1