background image

Nitrogen Generators 

Nitro35 Nitro70

29

11.

Notes

Summary of Contents for Nitro35

Page 1: ...User s manual Nitrogen Generators Nitro35 Nitro70...

Page 2: ...ts 1 Introduction 3 2 Safety 4 3 Description of the generator 6 4 Installation 9 5 Disassembly and transport 17 6 Use 18 7 Maintenance 24 8 Troubleshooting 26 9 Guarantee 27 10 Declaration of conformi...

Page 3: ...presumed that the user is expe rienced in the use of pneumatic components and in particular is aware of all sa fety aspects linked to the use of compressed air and nitrogen The margin of the text cont...

Page 4: ...RCES OF HEAT m Place the generators in an environment PROTECTED AGAINST RAIN AND WIND c NEVER OPEN the generator while it is connected to the electrical mains RISK OF FATAL INJURY BY ELECTROCUTION e R...

Page 5: ...n risk due to the structural failure of the components Pressure in the built in reservoir is limited by a safety valve 2 4 Technical assistance e CLAIND disclaims any liability for any damages caused...

Page 6: ...CD user s manual n 2 eyebolts for lifting the generator n 4 feet n 4 stabilizer brackets n 8 screw diameter 6mm lenght 20mm n 8 washers 3 2 Technical specifications 3 2 1 General requirements with th...

Page 7: ...emets 3 2 3 Gas Flow rate and purity degree of nitrogen outlet vary depending on the kind of uti lization and of application The technical specification of this model are indicated on the related prod...

Page 8: ...R GAUGE it indicates the compressed ari pressure of the intake line of the generator E PRESSURE REGULATOR it allows to set the outlet Nitrogen pressure A LABEL it shows the identificative data of the...

Page 9: ...ease avoid the direct exposition to sun beams 4 2 Generator positioning 4 2 1 Handling The packed generator can be handled using an adequate instrumentation such as a transpallet or a fork lift Once u...

Page 10: ...ea of the generator must consider a minumum access space for the user and for the maintenance we reccomend to let a free space of at least 50 cm both from the front panel and from the back panel 4 2 5...

Page 11: ...eumatic connections The picture shows the elements that constitute a tipycal Nitrogen generation plant The fittings for pneumatic connection of the various components of the plant Nitrogen generator c...

Page 12: ...he needs of the user in phase of purchase order The generator is set in CLAIND facilities at the requested purity and can t be reset by the user at a different purity without the intervention of quali...

Page 13: ...the working life of the Nitrogen generator In addition to the minimum requirement of pressure and flow rate specific of the model of the generator compressed air must comply to following specifica tio...

Page 14: ...of the generator the connection of air marked as AIR take the fitting 1 and mount it connect the pipe connect the other end of the pipe to the compressed air reservoir up fitting e we recommend to ins...

Page 15: ...daptors or multiple plugs when necessary please substitute the Schuko plug with another adequate plug Do always connect the protection conductor The power supply plug must be positioned in a easily ac...

Page 16: ...the momentaneus and more or less automatic insert of a spare gas sources e As a precaution the restart of a generator after the restoration of power supply isn t automatic but manual on command of th...

Page 17: ...crew the screws that block the stabilizers to the generator put this component in a bag and attached it to the generator m After removal the stabilizers pay attention to the handling of the ge nerator...

Page 18: ...the keypad DISPLAY The display is composed by two lines of 20 characters each The upper line usually shows the functions and parameters while the lower line displays the related status and values Sho...

Page 19: ...generator reaches the stand by condition In this condition the generator stops the normal production cycle and the display shows the message STAND BY 7 From this moment on Nitrogen is available in the...

Page 20: ...ION IN PROGRESS e PLEASE NOTE the START STOP key is not operative during a block of produc tion The following message appears at the end of pressurization GENERATOR READY At this time you have two alt...

Page 21: ...Where W WW Air pressure at the intake of the sieves in bar X XX pressure of Nitrogen in the reservoir in bar YYYY working phase of the molecular sieve CMS1 ZZZZ working phase of the molecular sieve CM...

Page 22: ...ys To acquire the selected value press the up arrow key while pressing the Func tion key Doing so you can also access to following parameter To exit this menu press the Fuction key for some seconds 6...

Page 23: ...key This value can be incre ased or decreased pressing the Function key and selecting the arrow key up or down To go back on main page press the Function key for some seconds e The default value is 6...

Page 24: ...for example WARNING EXHAUSTED SILENCER In order to acquire the message press the Function key The message di sappear following this operation and you can procede with normal operation The generator w...

Page 25: ...operation express in working hours of the generator e Warranty is granted only on original parts e Maintenance has to be effected only by technician authorized by Claind e If a correct maintenance sch...

Page 26: ...MINIMUM NITROGEN PRESSURE that has been set To shut down the alarm press the Function key To exit from the alarm mode the pressure inside the reservoir has to rise over the minimum value for example b...

Page 27: ...ut costs for technicians to visit the client s premises The guarantee covers exclusively COSTS DERIVING FROM MANUFACTURING DEFECTS and does not include 1 Damage caused by negligence or improper use of...

Page 28: ...chiarazione si riferisce conforme con quanto stabilito dalle seguenti disposizioni in particolare to which this declaration regards is fully in conformity with the following rules 2014 30 UE Direttiva...

Page 29: ...Nitrogen Generators Nitro35 Nitro70 29 11 Notes...

Page 30: ...Claind srl Via Regina 24 22016 Tremezzina Loc Lenno CO Italy Tel 39 0344 56603 Fax 39 0344 56627 e mail service claind it Nitro35 Nitro70 eng Rev6 fm...

Reviews: