4. Technical specifications

Model

DSX ELECTRONIC MPS

®

Part no.

27940 - 50 °C models 

Rated capacity / rated cur-
rent

18 kW..27 kW (26 A..39 A)

Chosen capacity / current

18 kW (26 A)

21 kW (30 A)

24 kW (35 A)

27 kW (39 A)

Electrical connection

  3/PE 380..415 V AC

3/PE 400 V AC

Min. required cable size

See note 1)

Hot water (l/min)
max. at Δt = 28 K

9,2

10,7

12,3

13,8

max. at Δt = 38 K

6,8

7,9

9,0

10,2

Rated volume

0,4 l

Type

Pressure type 1 MPa (10 bar)

Heating system

Bare wire heating system IES 

®

Required spec. water
resistance @ 15 °C

≥ 1100 Ωcm 

Spec. electrical conductivity

≤ 90 mS/m

Inlet temperature

≤ 70 °C

Flow rate to switch on

2,5  l/min

Pressure loss

20kPa at 2,5 l/min       130kPa at 9,0 l/min

Temperature choice

20 °C – 50 °C

Water connection

G ½“

Weight (when filled with 
water)

4,2 kg

VDE class of protection

I

Noise level test certificate

PA-IX 6822/I

Type of protection / safety

1) The cross sectional area of the connection cable must be in accordance with the power rating of the appliance and the specific 

requirements of AS/NZS 3000.

5. Dimensions

Dimensions in mm

231

97

231

97

170

100

466

56

363

 IP25

WMKA30016

AS 3498

Summary of Contents for Zip DSX ELECTRONIC MPS 27940

Page 1: ...Electronically controlled instantaneous water heater DSX 27940 50 C models Instructions for the user For 50 C models the appliance delivers water not exceeding 50 C in accordance with AS3498...

Page 2: ...1099 Servomotor with electronic 2 1 5 801099 Flow sensor 6 801101 Non return valve 7 DSX hood 8 Bottom part 9 Wall bracket 10 DSX connecting pipe 11 801102 PCB cover 2 1 12 Control panel support 13 Co...

Page 3: ...riate waste handling Please contact your local authority for further details of your nearest designated collection point Penalties may be applicable for incorrect disposal of this waste in accordance...

Page 4: ...n case of maintenance the appliance must be vented correctly in accordance with the instructions in this manual Do not remove the front cover under any circumstances before switching off the mains ele...

Page 5: ...Pa 10bar Heating system Bare wire heating system IES Required spec water resistance 15 C 1100 cm Spec electrical conductivity 90mS m Inlet temperature 70 C Flow rate to switch on 2 5 l min Pressure lo...

Page 6: ...6 Instructions for user 9120 34315 DSX 801049 November 2012 v1 00 6 Typical installations...

Page 7: ...Duschkabine ca 1950 466 363 56 100 170 Alternativer Kabeleingang 231 550 upper edge of the shower cabin approx 1950 lower edge of the appliance min 10 recommended approx 1200 upper edge of the wash b...

Page 8: ...sed or decreased in increments of 1 C by briefly pressing the up arrow and down arrow function keys Depressing the function key for a longer time changes the tempera ture continuously The temperature...

Page 9: ...activated or deactivated Working time Indication of total operating time of the heating given in seconds minutes days years Standby time Indication of the operating time since latest connection of the...

Page 10: ...to be adjusted Press the setup key and the info key simultaneously for at least 3 sec onds to call up the setup menu the display confirms by setup Using the arrow keys and to select the available mode...

Page 11: ...settings can be done Setting options h hours min minutes s seconds The info key selects the clock parameter to be changed h min or s The arrow keys and changes the set value shown Pressing the setup k...

Page 12: ...ory reset via key countdown not possible param eters can be seen but not be modified in setup menu 2 same as 1 additionally the setup menu cannot be opened 3 same as 2 additionally nominal value memor...

Page 13: ...display mode without an activated Energy and Status Monitor If the clock was enabled in the Setup menu it is only shown in normal display mode Note The menu items Power Flow Temp In Temp Out and Cost...

Page 14: ...ng excessively hot water Also any cold water added is not controlled by the electronic circuitry meaning that precise temperature control can no longer be guaranteed when supplying more than one outle...

Page 15: ...ircuit breaker tripped Reset circuit breaker STCO tripped Contact Zip Service to reset STCO Display flashes error symbol screwdriver Control system has switched off Switch power supply off and on If t...