Initial Use

1.  Fill the reservoir and flush it out until water discharges from all hot water taps bubble free, otherwise the tempera-

ture sensor and retainer will be damaged and require replacing.

2.  Check all water pipes and the connections for leaking water. 
3.  Switch on the power supply to the appliance.
4.  Press and hold the temperature selection key for 3 seconds to switch on the appliance. By pressing it again for 

3 seconds you can switch off the appliance.

5.  Select the operating temperature by briefly pressing the temperature selection button several times (see chapter 

“Setting the temperature”). 

6.  During heating, displaced water must drop from the discharge of the safety valve (closed operation) or out of the 

mixer tap (open operation). Monitor the first heating cycle. 

6. Initial operation

LED scale

Temperature selection key

Smart key

Smart indicator

Adjusting the temperature

Different temperature levels can be set by briefly pressing the temperature selection key several times. The temper-
ature rises in seven steps from 10 °C to a maximum of 75 °C. After reaching the maximum temperature, the selection 
starts again at 10 °C (frost protection) after pressing again. The four main applications are marked with corresponding 
symbols.

  – Frost protection (ca. 10°C)
  – Hand wash (ca. 35 °C)

 – ECO setting (ca. 57 °C)

  – Maximum temperature (ca. 75 °C)

The LED scale lights up when the key is pressed and displays the selected setpoint. The scale then changes back to the 
actual value display. The setpoint can be displayed again by briefly pressing the temperature selection button once.

If you are not operating the unit for a longer period of time, set the temperature to frost protection to save energy. 

7. How to use

Summary of Contents for S 30 Smart

Page 1: ...10 21 Gebrauchs und Montageanleitung Operating and installation instructions Warmwasserspeicher S30 Smart Water storage heater S30 Smart de 2 en 11...

Page 2: ...6 5 Installation 7 Ger t montieren 7 Wasseranschluss 7 Geschlossener Betrieb 8 Offener Betrieb 8 Elektroanschluss 8 6 Inbetriebnahme 9 Erstinbetriebnahme 9 7 Bedienung 9 Temperatureinstellung 9 Smart...

Page 3: ...ffnen Sie niemals das Ger t ohne vorher die Strom zufuhr zum Ger t dau erhaft unterbrochen zu haben Nehmen Sie am Ger t oder an den Elektro und Wasser leitungen keine tech nischen nderungen vor Das G...

Page 4: ...g w hrend dem Betrieb 7 Der Leiterquerschnitt der elektrischen Anschl sse ist gem den technischen Spezifikationen zu dimensionieren Brandgefahr durch berhitzung der elektrischen Leitungen 8 Alle Siche...

Page 5: ...g verhindert oder so klein wie m glich gehalten wird Andernfalls muss die Trinkwasseranlage mit einer W rmebehandlung saniert werden Stagnierendes Wasser Um langanhaltende Stagnation zu vermeiden muss...

Page 6: ...as Typenschild ist in der N he der Wasseranschlussleitungen angebracht 4 Umwelt und Recycling Ihr Produkt wurde aus hochwertigen wiederverwendbaren Materialien und Kompo nenten hergestellt Beachten Si...

Page 7: ...odass unn tiger W rmeverlust durch lange Rohrleitungen vermieden wird A in Abb 2 Zur Wartung des Ger tes ist ein Freiraum von mindestens 50cm unterhalb des Speichers vorzusehen um an die Elektronikkom...

Page 8: ...einzustellen Zwischen den Sicherheitsbaugruppen und dem Speicher darf kein Absperrventil montiert werden Der Ablauf des Sicherheitsventils muss immer offen sein Die Sicherheitsventil Kombination muss...

Page 9: ...ffener Betrieb tropfen Das erste Aufheizen berwachen 6 Inbetriebnahme Temperatureinstellung Durch mehrfaches kurzes Dr cken der Temperaturwahltaste k nnen verschiedene Temperaturstufen eingestellt wer...

Page 10: ...seitigen Verwenden Sie ausschlie lich Original Ersatzteile 8 Wartung Reinigung und Pflege Wartungsarbeiten d rfen nur von einem anerkannten Fachhand werksbetrieb durchgef hrt werden 7 Bedienung Smart...

Page 11: ...ratureinstellung am Ger t pr fen Zu viel Warmwasser in kurzer Zeit entnommen Aufheizvorgang abwarten Smart Funktion hat Leistung gedrosselt Smart Funktion deaktivieren Temperaturanzeige blinkt wiederh...

Page 12: ...cycling 16 5 Installation 17 Installing the appliance 17 Water connection 17 Closed operation 18 Open operation 18 Electrical connection 18 6 Initial operation 19 Initial Use 19 7 How to use 19 Adjust...

Page 13: ...not remove the front cover under any circumstances before switching off the mains electrical supply to the unit Never make technical modifications either to the appliance itself or the electrical lead...

Page 14: ...components 6 Install the appliance on a solid wall that is not adjacent to bedrooms Falling of the appliance due to collapse of the wall or noise during operation 7 Make all electrical connections us...

Page 15: ...not grow or have minimum growth wherever possible Otherwise it is necessary to disinfect a drinking water installation by means of a thermal treatment Stagnation of the water To avoid long periods of...

Page 16: ...e refer to the information provided on the data plate label locat ed near the water inlet and outlet pipes 4 Environment and recycling Your product was manufactured from high quality reusable material...

Page 17: ...ppliance to put it on the bracket and for maintenance works 2 Fix the wall bracket to the wall using screws and dowels with sufficient load bearing capacity 8mm 3 Hook the water heater onto the bracke...

Page 18: ...lways be open The safety valve combination for closed operation must be accredited Note In compliance with the Energy Conservation Act the temperature of the water heater should be limited to 60 C for...

Page 19: ...Monitor the first heating cycle 6 Initial operation LED scale Temperature selection key Smart key Smart indicator Adjusting the temperature Different temperature levels can be set by briefly pressing...

Page 20: ...tank with water and draining it com pletely so as to remove any residual impurities Only use original spare parts Maintenance work must only be conducted by an authorised professional 8 Maintenance an...

Page 21: ...y Check fittings and hose connections Water does not heat up Check fuse and electrical connection Contact customer service department to check thermal cut out thermostat or heating element if necessar...

Page 22: ...auf unterschiedlichen Testbedingungen Der Energieverbrauch wurde nach einem standardisierten Verfahren nach EU Vorgaben ermittelt Der reale Energiebedarf des Ger tes h ngt von der individuellen Anwen...

Page 23: ...CLAGE 23 B A 100 100 445 C 350 420 G G1 2 2 1 3 Dimensions in mm Abmessungen in mm 11 Abbildungen Figures 235 310 510 200...

Page 24: ...Ausf hrung und Irrtum vorbehalten Subject to technical changes design changes and errors 9120 91895 10 21 CLAGE GmbH Pirolweg 4 21337 L neburg Deutschland Telefon 49 4131 8901 0 E Mail service clage d...