CLAGE
19
Initial Use
1. Fill the reservoir and flush it out until water discharges from all hot water taps bubble free, otherwise the tempera-
ture sensor and retainer will be damaged and require replacing.
2. Check all water pipes and the connections for leaking water.
3. Switch on the power supply to the appliance.
4. Press and hold the temperature selection key for 3 seconds to switch on the appliance. By pressing it again for
3 seconds you can switch off the appliance.
5. Select the operating temperature by briefly pressing the temperature selection button several times (see chapter
“Setting the temperature”).
6. During heating, displaced water must drop from the discharge of the safety valve (closed operation) or out of the
mixer tap (open operation). Monitor the first heating cycle.
6. Initial operation
LED scale
Temperature selection key
Smart key
Smart indicator
Adjusting the temperature
Different temperature levels can be set by briefly pressing the temperature selection key several times. The temper-
ature rises in seven steps from 10 °C to a maximum of 75 °C. After reaching the maximum temperature, the selection
starts again at 10 °C (frost protection) after pressing again. The four main applications are marked with corresponding
symbols.
– Frost protection (ca. 10°C)
– Hand wash (ca. 35 °C)
– ECO setting (ca. 57 °C)
– Maximum temperature (ca. 75 °C)
The LED scale lights up when the key is pressed and displays the selected setpoint. The scale then changes back to the
actual value display. The setpoint can be displayed again by briefly pressing the temperature selection button once.
If you are not operating the unit for a longer period of time, set the temperature to frost protection to save energy.
7. How to use