3

1. Sicherheitshinweise

1. Safety instructions

• 

Do not remove the front cover under any circumstances before 
switching off the mains electrical supply to the unit.

• 

Never make technical modifications, either to the appliance 
itself or the electrical leads and water pipes.

• 

Pay attention to the fact that water temperatures in excess of 
approx. 43 °C are perceived as hot, especially by children, and 
may cause a feeling of burning. Please note that the fittings 
and taps may be very hot when the appliance has been in use 
for some time. At small tapping rates below 1,5 l/min high 
temperature variations  are possible. Please avoid such small 
tapping rates.

• 

Water inlet temperature must not exceed 70 °C. This tempera-
ture limitation  is ensured under normal operation conditions 
by the fresh water unit. IMPORTANT: The maximum tempera-
ture of the solar buffer tank must  not exceed 80 °C.

• 

After an electrical power outage or a reconnection of the 
230 V connection, the fresh water station starts with a pur-
ging programm for 60 seconds. During this time the outlet 
temperature is not adjustable.

• 

In case of malfunction, disconnect the fuses immediately. In 
case of leaks, cut off the cold water supply instantly. Repairs 
must only be carried out by the customer service department 
or an authorised professional.

• 

This appliance can be used by children aged from 8 years and 
above and persons with reduced physical, sensory or mental 
capabilities or lack of experience and knowledge if they have 
been given supervision or instruction concerning use of the 
appliance in a safe way and understand the hazards involved. 
Children shall not play with the appliance. Cleaning and user 
maintenance shall not be made by children without supervi-
sion.

Hinweisen in der Anleitung ordnungsgemäß entlüftet werden.

• 

Öffnen Sie niemals das Gerät, ohne vorher die Stromzufuhr 
zum Gerät dauerhaft unterbrochen zu haben. 

• 

Nehmen Sie am Gerät oder an den Elektro- und 
Wasserleitungen keine technischen Änderungen vor. 

• 

Beachten Sie, dass Wassertemperaturen über ca. 43 °C 
besonders bei Kindern als heiß empfunden werden und ein 
Verbrennungsgefühl hervorrufen können. Bedenken Sie, dass 
nach längerer Durchlaufzeit auch die Armaturen entsprechend 
heiß werden. Bei kleinen Zapfmengen von unter 1,5 Liter/min 
kann die Warmwassertemperatur schwanken. Vermeiden Sie 
kleine Zapfmengen. 

• 

Die Wassereinlauftemperatur darf nicht höher als 70 °C sein.  
Diese Temperaturbegrenzung wird über die Frischwasser-
einheit der FWX SOLARTRONIC im Regel betrieb sicher gestellt. 
WICHTIG: Die Speichermaximaltemperatur darf 80°C nicht 
überschreiten.

• 

Nach einem Stromausfall oder 230 V Wiederanschluss der 
Station startet ein Spül- und Entlüftungsprogramm der 
Frischwassereinheit über 60 Sekunden. Während dieser Zeit 
fördert die Primärkreispumpe mit 100% Förderleistung. 
Warmwasseraustrittstemperatur kann in dieser Zeitspanne 
nicht reguliert werden.

• 

Im Störungsfall schalten Sie sofort die Sicherungen 
aus. Bei einer Undichtigkeit am Gerät schließen Sie 
sofort die Kaltwasserzuleitung. Lassen Sie die Störung 
nur vom Werkskundendienst oder einem anerkannten 
Fachhandwerksbetrieb beheben. 

• 

Dieses Gerät kann von Kindern ab 8 Jahren und darüber sowie 
von Personen mit verringerten physischen, sensorischen oder 
mentalen Fähigkeiten oder Mangel an Erfahrung und Wissen 
benutzt werden, wenn sie beaufsichtigt oder bezüglich des 
sicheren Gebrauchs des Gerätes unterwiesen wurden und 
die daraus resultierenden Gefahren verstehen. Kinder dürfen 
nicht mit dem Gerät spielen. Reinigung und Benutzer-Wartung 
dürfen nicht von Kindern ohne Beaufsichtigung durchgeführt 
werden.

Summary of Contents for FWX SOLARTRONIC

Page 1: ...C Frischwasserstation mit integriertem Durchlauferhitzer zur Nacherwärmung Gebrauchsanleitung für den Anwender Fresh water station with integrated instantaneous water heater for top up heating Operating instructions for the user ...

Page 2: ...pply The appliance must never be exposed to frost The appliance must be connected to the protective conductor The minimal specific water resistance must not fall below the value stated on the label The maximum water pressure must not exceed the value on the label Before commissioning for the first time and each time the appliance is emptied e g due to work on the plumbing sys tem if there is a ris...

Page 3: ... children without supervi sion Hinweisen in der Anleitung ordnungsgemäß entlüftet werden Öffnen Sie niemals das Gerät ohne vorher die Stromzufuhr zum Gerät dauerhaft unterbrochen zu haben Nehmen Sie am Gerät oder an den Elektro und Wasserleitungen keine technischen Änderungen vor Beachten Sie dass Wassertemperaturen über ca 43 C besonders bei Kindern als heiß empfunden werden und ein Verbrennungsg...

Page 4: ...er heating Due to the demand oriented hot water heating device the need for inefficient high tem perature levels is obsolete Die FWX SOLARTRONIC Station ist ein elektronisch geregeltes Warm wasser gerät bestehend aus einer Frisch wasser station und einem integrier ten Durch lauferhitzer zur zentralen oder dezen tralen Erwärmung von Trink wasser an einer oder mehreren Zapfstellen Die Frischwasserei...

Page 5: ... Plattenwärmetauscher und Durchlauferhitzereinheit die Warmwasser temperatur gemes sen nach der Durchlauferhitzereinheit As soon as you open the hot water tap the FWX SOLARTRONIC switches on auto ma ti cally When the tap is closed the appliance automatically switches off Temperature setting You can set the required temperature gradually to a lower or higher value with the arrow keys and The temper...

Page 6: ...lwertes der Frischwasser reinheit Menüpunkt Reihenfolge Info Menü Menu item order of Info menu Info menu The info menu offers a variety of display values that provide information on vari ous parameters of the FWX SOLARTRONIC station The values can be displayed only Press the info key for at least 3 sec onds to call up the info menu the display confirms by info menu Using the arrow keys and you can...

Page 7: ... die oben genannten Werte zu Ihrer Information an Power Indication of current power consumption kW Control value Indication of calibration value of the control system Diagnostics Indication of the last ten diagnostic messages Signal Indication of the current I2 C connection quality in Software version Information about installed software version Note Values of the info menu cannot be modified or e...

Page 8: ...weis Im Info Menü unter FRIWA Sollwert wird der einge stellte Wert direkt angezeigt Setup menu The setup menu offers a variety of adjust abilities affecting the performance and the display of the appliance Press the setup key and the info key simultaneously for at least 3 seconds to call up the setup menu The display con firms with setup Using the arrow keys and you can switch to the individual pa...

Page 9: ...tup Menü nicht aufgerufen werden 3 wie 2 zusätzlich Sollwertspeicher Hand Dusche Wanne Küche nicht änderbar 4 wie 3 zusätzlich Sollwert nicht änderbar Charges per kWh ct The electricity tariff can be entered Setting options from 0 ct to 199 90 Aux display Activation of additional parameters Setting options t 1 inlet temperature C Po power kW FL flow rate l min no additional display Note When addit...

Page 10: ...e limitation The FWX SOLARTRONIC station is equipped with an optional temperature limiting function This scalding protection is deactivated in the works setting Switch on select the limit tem per ature with arrow keys and then press info key and arrow key simultaneously for at least 3 sec The display briefly confirms the activation by temp protection enabled After activation of the scalding pro te...

Page 11: ... Einlauftemperatur den vorge wählten Sollwert übersteigen wird keine Leistung abgegeben die Anzeige zeigt Einlauf zu heiss an Reset to factory setting All factory settings can be recalled Press setup key the display now counts backwards from 10 to 00 in second intervals The appliance is reset at value 00 if you stop press ing the key earlier the process will be canceled How to save energy Set the ...

Page 12: ... der Durchlauferhitzer luftfrei ist 4 Erst dann dürfen Sie die Stromzufuhr zum Durchlauferhitzer wieder ein schalten und den Strahlregler wieder einschrauben Venting after maintenance work outside the station The FWX SOLARTRONIC features an automatic air bubble protec tion to pre vent it from inadver tently running dry Nevertheless the appliance must be vent ed before using it for the first time E...

Page 13: ...ehr aus der Leitung austritt 8 Schalten Sie die 230 V Versorgung der Frischwassereinheit ein 9 Schalten Sie nun die Spannungs versorgung des Durchlauferhitzers wieder ein Maintenance work must only be con ducted by an authorised professional Cleaning and replacing the filter strainer The cold water connection connection I of the fresh water unit is equipped with a ball valve and a filter strainer ...

Page 14: ...hhand werks betrieb überprüfen um die einwand freie Funktion und Betriebs sicherheit jederzeit zu gewährleisten Plastic surfaces and fittings should only be wiped with a damp cloth Do not use abrasive or chlorine based cleaning agents or solvents For a good water supply the outlet fit tings jet regulators and shower heads should be unscrewed and cleaned at regular intervals Every three years the e...

Page 15: ...xt try to remedy the problem with reference to the following table In doing so you will avoid unnecessary expense of customer service assistance Problem Cause Solution Water stays cold digital display does not light up Master fuse tripped Renew or activate fuse Display shows error sym bol screwdriver Control system has switched off Switch fuses off and on If symbol screwdriver is still indicated c...

Page 16: ...ck reference guide Temperatur einstellen Set temperature 1 1 C 1 C Info Menü ansehen Info menu 2 1 4 3 5 Zurücksetzen der Werksinstellungen Reset 1 Drücken halten Press hold Zurücksetzen abgeschlossen Reset completed 3 2 Verbrühungsschutz ein Scalding protection on Drücken Press 3 Sek 1 2 Display bestätigt Aktivierung Display confirms activation 3 Verbrühungsschutz aus Scalding protection off 1 Di...