[SM-206790-A/5]
−
4
−
f) Avoid using the solenoid valve system in a humid en-
vironment because the humidity is likely to cause
condensation with a change in the temperature.
g) Do not use the normal type solenoid valves for an ap-
plication that requires conformity with explosion-proof
specifications. Choose explosion-proof solenoid
valves instead.
h) The packing and gaskets may deteriorate sooner than
usual if used in an atmosphere with a higher than
normal density of ozone (for example, the atmosphere
near a beach or in an area with frequent thunder-
storms).
Consult us for the packing and gaskets to be used in an
atmosphere with a higher ozone density.
INSTALLATION (Section 4.2)
When installing a solenoid valve unit, never attempt to
hold it in position by means of the pipes connected to it.
Mount the solenoid valve by applying the mounting screws
and/or mounting plate to the solenoid valve.
!
WARNING :
!
CAUTION :