[SM-206790-A/5]
−
36
−
SPECIFICATIONS
8
8. PRODUCT SPECIFICATIONS AND HOW TO ORDER
8.1 Product Specifications
1) Specifications
Model code
4KA210
2-pos. Single
4KA220
2-pos. Double
4KA230
3pos. All ports
blocked
4KA240
3-pos. Load
ports open to
exhaust ports
4KA250
3-pos. Load
ports open to
supply ports
JIS Symbol
Item
Working fluid
Compressed air
Valve type and operation
Pilot operated soft spool valve
Min. working pressure
MPa
0.15
0.1
0.2
Max. working pressure
MPa
0.7
Proof pressure
MPa
1.05
Port
size
Supply port
P
Rc1/8 (Option :
φ
6,
φ
8 push-in joint)
Cylinder ports
A
・
B
Exhaust ports
R1
・
R2
Rc1/8
Flow characteristics C(Sonic con-
ductance) dm
3
/(s
・
bar)
2.6
2.3
2.9
2.3
Ambient temperature
(Note 1)
℃
-5 to 50 (No freezing)
Fluid temperature
℃
5 to 50
Response time
ms
30 or less
60 or less
Lubrication
Not required (Use turbine oil type 1, ISO VG32 when required)
Protection structure
Dust-proof
Manual operation device
Non-locking type (Option : Locking type)
Weight
g
115
155
170
Electrical specifications
Rated voltage
(V)
AC100V (50 / 60Hz)
AC200V (50 / 60Hz)
DC24V
Starting current
(A)
0.056 / 0.044
0.028 / 0.022
0.075
Holding current
(A)
0.028 / 0.022
0.014 / 0.011
Power consumption
(with indicator light)
(W)
1.8 / 1.4 (2.0 / 1.6)
1.8 (2.0)
Temperature rise
(
℃
)
43
Voltage fluctuation
±
10%
Thermal class
B(molded coil)
Electrical connections
Grommet with lead wire
(Option : Small terminal box, Plug-in connectors)
Surge suppressor
Option
Indicator
Option (with indicator light)
Above-mentioned response time is the figure on the non-lubricated at 0.5 MPa, and depends on
the pressure and quality of lubricant.
Pressure is converted as 1MPa=10.1972kgf/cm
2
≒
10.2kgf/cm
2
In case of use, consult separately of the continous energizing.
Note 1) Ambient temperature is the room temperature while component is stored or assembled
system is standing still and it differs from that of running media in operation.
a
A B
R1 P R2
b
a
A B
R1 P R2
b
A B
R1 P R2
b
a
A B
R1 P R2
b a
A B
R1 P R2
b