11
RDM_TRAFFIC_ENABLE (editable, 01 = enable, 00 = disable)
OUTPUT_POWER (editable, 00=1mW, 01=14mW, 02=28mW, 03=72mW)
In order to allow RDM traffic and discovery and control of connected Responders you must
enable RDM Traffic (Set RDM_TRAFFIC_ENABLE to 01).
Note that DMX transmission fidelity may be slightly reduced when RDM Traffic is enabled.
Installing the Mounting Bracket
The SHoW DMX SHoW Baby is provided with a Mounting Bracket for use with ½” theatrical
mounting hardware like a C-Clamp.
Mount the Bracket on the SHoW DMX SHoW Baby using the 3 provided 8-16 x .250 Flat Head
Torx drive screws. These are special screws for use with plastic, and need a T15 Torx driver.
Do not over-tighten the screws!