11
5 Configuration
5.1 Installation
The QolorPIX Tape Controller requires standard AC power from 90-260V, 50/60 Hz. The front
panel provides an AC in and through connection via Neutrik powerCON TRUE1.
Mounting accessories are included to provide mounting with two c-clamps or in a typical 19-inch
rack. The QolorPIX Tape Controller uses 2U mounting spaces.
When unit is installed ensure that the air vents on either side of the box are not covered.
If unit is being controlled via DMX512 ensure that the last unit in the chain is properly terminated
with a 120
Ω
½
watt resistor between pins 2 and 3. A DMX connector with a built in terminating
resistor is available from your local distributor.
5.2 Menu
To lock the menu, press and hold both the "Up" and "Down" buttons for two seconds until
"LOCKED" is displayed.
To unlock the menu, press and hold both the "Up" and "Down" buttons for two seconds until
"UNLOCKED" is displayed.
5.3 Menu Descriptions
5.3.1 Save
The “Save” menu option will save any configuration changes since last power on.
If configuration changes are not explicitly saved, they will be lost on power off.
Changes made through RDM are automatically saved.
5.3.2 Restore
The “Restore” menu option can be used to reset the device configuration to factory defaults.
5.3.3 Port Settings
The “Port Settings” menu option allows you to configure each port. Changes can be
made globally or individually by port. Only changed values are applied. For example, you
can change the number of pixels of every port without changing any of the ports’
addresses.