10. All-Reset Procedure
Perform the all-reset procedure described below
after replacing the battery or when the watch does
not run properly or has an abnormal display due to
a strong impact (such as when there is no display
showing or when the alarm sounds completely).
(1) Press button 

A

B

C

and 

M

simultaneously.

* All cells and the EL internal illumination will
light during the time the buttons are pressed.
* The displays of all cells will continue to be lit
from the time the buttons are released until the
next button is pressed or until 60 seconds have
elapsed. (EL internal illumination will be turned
off when the buttons are released.)

(2) Following completion of the all-reset procedure,

reset each of the modes before using the watch.

11. Precautions
CAUTION: Water-resistance performance
There are several types of water-resistance
watches, as shown in the following table. 
For correct use within the design limits of the
watch, confirm the level of water-resistance 
of your watch, as indicated on the dial and 
the case, consult the table.

* (The unit “bar” is roughly equal to 1
atmosphere.)

* WATER RESIST(ANT) xxbar may also be

indicated as W.R.xxbar

Water-resistance for daily use (to 3 atmospheres):
This type of watch is water-resistant to minor
exposure to water. For example, you may wear the
watch while washing your face; however it is not
designed for use underwater.

Upgraded water-resistance for daily use 
(to 5 atmospheres): 
This type of watch is water-
resistant to moderate exposure to water. You may
wear the watch while swimming, but it is not
designed for use while skin diving.

Upgraded water-resistant for daily use (to 10/20
atmospheres): 
This type of watch may be used for
skindiving; however it is not designed for scuba or
saturated diving such as helium gas.

CAUTION
• Do NOT operate the button with wet fingers or

when the watch is wet. Water may enter the watch
and compromise the water-resistance.

• If the watch is used in seawater, rinse with fresh

water afterward and wipe with a dry cloth.

• If moisture has entered the watch, or if the inside

of the crystal is fogged up and does not become
clear within a day, immediately take the watch to
your dealer or Citizen Service Centre for repair.
Leaving the watch in such a state will allow
corrosion to form inside.

• If seawater enters the watch, place the watch in a

box or plastic bag and immediately take it in for
repair. Otherwise, pressure will increase, and parts
(crystal, buttons, etc) may come off.

Indication

Minor exposure to

water (washing
face, rain, etc.)

Dial

WATER RESIST

or no indication

WR 50 or

WATER RESIST

50

WR 100/200 or

WATER RESIST

100/200

Case

(Case back)

WATER

RESIST(ANT)

WATER 

RESIST(ANT) 5

bar or WATER

RESIST(ANT)

WATER

RESIST(ANT) 

10 bar / 20 bar or

WATER

RESIST(ANT)

Specifications

Water-resistant to

3 atmospheres

Water-resistant to

5 atmospheres

Water-resistant to

10/20

atmospheres

OK

OK

OK

NO

OK

OK

NO

NO

OK

NO

NO

NO

NO

NO

NO

NO

NO

NO

moderate

exposure to water
(washing, kitchen,

work swimming,

etc.)

Marine sports

(skin diving)

Scuba diving 

(with air tank)

Saturation diving
(helium enriched

environment

Operation of the

crown with

moisture visible

Examples of Use

Summary of Contents for AIR DUNK ME5 series

Page 1: ...ols indicated in this diagram The design may differ slightly depending on the model Name Time date basketball timer Timer Chronograph Alarm Button A When pressed Date display month date day Basketball timer correction Timer correction Split time rest Alarm ON OFF switching alarm time correction Button B Button C When pressed once _________ Start stop Start stop Start stop Alarm correction mode Whe...

Page 2: ...rapidly Timer Measurement 1 The timer starts to count down from the set time when button B is pressed 2 The timer is stopped by pressing button B during measurement The timer is restarted by pressing button B again after the timer is stopped 3 Pressing button A when the timer is stopped returns the watch to the initial set value after which the timer begins to count down again from the set value 7...

Page 3: ...ly causes the display to advance rapidly 4 Press button B after correcting the minutes to return the watch to the normal alarm display Switching the Alarm On and Off The alarm is switched on and off each time button A is pressed during the normal alarm display Duration of Alarm Tone The alarm tone sounds for approximately 15 seconds Turning Off the Alarm Tone The alarm tone can be turned off by pr...

Page 4: ... moderate exposure to water You may wear the watch while swimming but it is not designed for use while skin diving Upgraded water resistant for daily use to 10 20 atmospheres This type of watch may be used for skindiving however it is not designed for scuba or saturated diving such as helium gas CAUTION Do NOT operate the button with wet fingers or when the watch is wet Water may enter the watch a...

Page 5: ...ar Doing so may result in deterioration of the watch such as deformation of plastic parts Do NOT place the watch close to a magnet Timekeeping will become inaccurate if you place the watch close to magnetic health equipment such as a magnetic necklace or a magnetic latch of a refrigerator door or handbag clasp or the earphone of a mobile phone If this has occurred move the watch away from the magn...

Reviews: