background image

 

 

 

 

 
GUIDE 

Cat. No. 42.7003 
Instruction Manual 

 

 
 
 
 
 
 
 

 

INTRODUCTION 

This device is a digital product that provides altimeter, barometer, compass, altimeter data, dual time,  
chronograph, chronograph data and alarm functions.  
 

Features: 
Altimeter 

- 1 meter (or foot) resolution and with working range from  -700 meters (-2296 feet) to 9000 meters (29520 feet).  
- Graphical expression of changes provided. 
- Unit in meters or feet selectable.  
- 20 memories with date, time and altitude reading.  

Barometer 

- 1 hPa resolution and with working range from 300 hpa to 1100 hpa.  
- Graphical expression of changes provided. 
- Both sea level pressure and absolute pressure can be shown.  
- Weather forecast. 
- Temperature displayed in °F or °C selectable. 

Compass 

- Electronic compass providing 16 cardinal indications together with bearing in degrees.  
- Declination correction provided. 

Time 

- 2 time modes selectable. 
- Presents day of the week, day, hours, minutes and seconds (year and month can also be set).  
- 12/24-hour formats selectable. 
- Auto-calendar from 2000 to 2049. 

Summary of Contents for 42.7003

Page 1: ...ectable 20 memories with date time and altitude reading Barometer 1 hPa resolution and with working range from 300 hpa to 1100 hpa Graphical expression of changes provided Both sea level pressure and absolute pressure can be shown Weather forecast Temperature displayed in F or C selectable Compass Electronic compass providing 16 cardinal indications together with bearing in degrees Declination cor...

Page 2: ...rm 2 daily alarms Hourly chime Electro luminescent backlight 3 seconds light up EL backlight Altimetermode with altitude change measures every 2 5 seconds Altimetermode without altitude change barometer mode every 2 5 minutes Barometermode measures every 2 5 minutes Changes to Time mode after 24 hours Temperature measures every 2 5 minutes ...

Page 3: ... ALTITUDE PRESS AND HOLD REVERSE SELECTION OF ALTITUDE DATA STOP CHRONOGRAPH STORE CHRONOGRAPH DATA PRESS AND HOLD SELECT RUN NUMBER SWITCH BETWEEN ALARM 1 AND ALARM 2 REVERSE SETTING SET OR CALIBRATION C MODE CHANGE DIRECT CHANGE TO TIME MODE PRESS AND HOLD ADVANCE TO NEXT SETTING SET OR CALIBRATION D EL BACKLIGHT ENTER SET OR CALIBRATION PRESS AND HOLD CLEAR DATA PRESS AND HOLD EXIT SET OR CALIB...

Page 4: ...ograph Data and Alarm Press C to change from mode to mode hold down B to switch between Normal Time mode and Dual Time mode as in the following At any mode holding down C will change to Time mode directly NORMAL TIME COMPASS BAROMETER ALTIMETE ALTIMETER DATA C C C C DUAL TIME Hold B CHRONOGRAPH CHRONOGRAPH DATA ALARM C C C C ...

Page 5: ...he mode indicator T1 or T2 stops flashing to switch between Normal Time mode and Dual Time mode To switch among the 3 time displays Use A or E to switch among the 3 displays for time TIME BAROMETER or WEATHER is displayed first Graph of sea level pressure is described in BAROMETER MODE To set time 1 Hold down D until the hour digits start to flash on the display which indicates the setting screen ...

Page 6: ...ass mode Mode prompt COMP is displayed first and bearings will be taken automatically Compass mode indicator is shown When you take bearings readings are shown in 16 cardinal indications together with bearing in degrees Reading shown indicates the direction that the LCD s 12 o clock position is pointing to North South arrow is shown on circumference of the LCD North is indicated by 1 flag and Sout...

Page 7: ... for information of declination Declination angles for major cities are listed below for reference only City Declination Angle City Declination Angle City Declination Angle Anchorage 22 E London 4 W Rio De Janeiro 21 W Atlanta 4 W Little Rock 3 E San Francisco 15 E Bombay 1 W Livingston MT 14 E Seattle 19 E Boston 16 W Munich 1 E Shanghai 5 W Calgary 18 W New York City 14 W Toronto 11 W Chicago 3 ...

Page 8: ...oning for at least 12 hours Temperature is of 0 1 degree resolution and with working range from 4 F 20 C to 158 F 70 C And unit in F or C selectable There are 3 displays for Barometer mode To switch among the 3 displays for barometer mode Use A or E to switch among the 3 displays for barometer mode Reading the graph of sea level pressure The graph shows the relative changes in sea level pressure i...

Page 9: ... pressure reading starts to flash 3 Use A and B to change the setting Holding down either button scrolls the setting at high speed 4 Press D to exit the setting screen If there is no button operation for 2 3 minutes at setting screen the display will return to Barometer mode automatically To set current weather 1 Hold down D until SET CURRENT WEATHER scrolls on the display which indicates the weat...

Page 10: ...n represe nts the relative reading of altitude in that time It is not possible to get the exact reading from the graph User can only get the trend of changes from the graph To switch between meters and feet Hold down B until the unit indicator M or Ft stops flashing to switch altitude reading between meters and feet To store altitude data Hold down A until DATA stops flashing to store the current ...

Page 11: ... data cannot be cleared individually CHRONOGRAPH MODE Use C to enter Chronograph mode Mode prompt CHRO is displayed first The chronograph is of 1 100 second resolution for the first hour and 1 second resolution for the rest and with working range up to 24 hours then the chronograph stops automatica lly For the first hour the chronograph shows minutes seconds and 1 100 seconds then it shows hours m...

Page 12: ...e display Data of the current run is stored and chronograph is reset to all zeros To measure two or more finishes 1 Press A to start a time measurement 2 Press A again when the first runner finishes 3 Press A again when the second runner finishes You may record the finish time of up to 100 runners by pressing A 4 Press B when the last runner finishes Time measurement is stopped 5 Hold down B until...

Page 13: ...ng chronograph data cannot be cleared To retrieve the chronograph data 1 Use B to select the run to be retrieved Run number and date are shown for about 2 seconds first 2 Press A to retrieve the data one by one Display examples To clear one particular run 1 Use B to select the run to be cleared 2 Hold down D until CLEAR HOLD ALL is shown on the display release D and the selected run will be cleare...

Page 14: ...d by AL 1 and alarm 2 indicated by AL 2 To set alarm time and turn chime on and off 1 Hold down D until the hour digits start to flash on the d isplay which indicates the setting screen 2 Use A and B to change the setting Holding down either button scrolls the setting at high speed 3 Press C to advance to the next setting as in the following When TIME 1 or TIME 2 is flashing press A or B to switch...

Page 15: ...e will not be any measurement of altitude pressure or temperature until A C or E is pressed After reset entering Compass mode will change to calibration screen directly BATTERY REPLACEMENT Replace the exhausted battery with a CR2032 cell or equivalent Please contact a specialized dealer for battery change Thereby the sealing ring must not be damaged No guarantee if the instrument is handled or ope...

Reviews: