Installation Summary
AC Power Source
This product operates from an electrical source rated as indicated in Table 4.
Power each cabinet from a separate branch circuit wired in accordance with
local electrical codes
Equipment Location
Locate this product in a clean and dry environment only, according to
environmental and other installation requirements specified in Table 4
Power Distribution Cables
For a new installation, or to replace a damaged/defective power cord, provide
a flexible, three-conductor power cord that
• complies with local electrical codes
• has a voltage and current rating not less than the rating marked on this
product
• has a polarized attachment plug with a current rating not less than 125
percent of the rating marked on this product
• has a usage rating for floor mounted products (a typical example in the US
would be an "S" or "SJ" rated cord)
• is not longer than 2.4 meters
Fuse and Component Replacement
Unauthorized repair of this product may result in a fire, shock hazard, defective
operation, and/or equipment damage. Do not repair or replace components on circuit
card assemblies or other parts of this equipment unless there is a specific
description of the procedure provided in the technical documentation. Return all
inoperative assemblies to an authorized CITEL agent for repair