Page 1: ...SUPER FOAM DOMETM Operating Instructions P N 100216 120 VAC ...

Page 2: ...product is quite extensive To guarantee perfect and successful work with this machine please take some time to read the manual carefully And finally we believe you will enjoy years of great foam effects if you care for and maintain your SUPER FOAM DOMETM CITC 1420 80th St SW D Everett WA 98203 888 786 CITC www citcfx com ...

Page 3: ... DomeTM 5 5 1 Selecting the location 5 2 Electrical Power Requirements 5 3 Hooking things up 5 4 Operating the machine 5 5 Cleanup 5 6 Troubleshooting 6 Service and Maintenance 9 6 1 Super Foam DomeTM Pump Information 6 2 Getting the most from your Super Foam DomeTM Pump 7 Technical Data 10 8 Limited Warranty Conditions 11 ...

Page 4: ...ducts you ordered are supplied 3 Description of the Super Foam DomeTM The Super Foam DomeTM makes massive amounts of foam 500 cubic feet per minute 14m3 min quickly and harmlessly with its high powered quiet fan It will actually fill a 20 x 20 x 6 pit in less than 5 minutes The Super Foam DomeTM uses a clean harmless and biodegradable fluid to make foam which will last 5 to 10 minutes in dry condi...

Page 5: ...esulting from contact with both current carrying conductors of an electrical circuit 3 Do not connect an extension cord longer than 100 feet to the GFI output to avoid the possibility of nuisance tripping 4 Test frequently and before each use to ensure proper operation by following operating instructions in section 3 2 5 DO NOT USE where water may enter GFI case 6 DO NOT MODIFY OR IMMERSE this dev...

Page 6: ...g circuits consult a qualified electrician 2 You must have both units connected through the Ground Fault Interrupter GFI in order to use this device 1 Plug GFI into a well grounded 120VAC 20A circuit If you have any doubt about the circuit s safety ground plug in testers are available to test the outlet If in doubt discontinue trying to power this unit until the outlet can be checked by an electri...

Page 7: ...e is an irritant to eyes Wear eye protection and gloves when mixing If concentrate contacts eyes immediately wash with plenty of water for 15 minutes while lifting eyelids Consult a physician Prolonged contact with skin may cause irritation Wash with water If clothing is wet with material change to clean clothes and wash affected skin Not food quality Do not digest If digested treat as dish soap O...

Page 8: ... power switch should be OFF The GFI should be plugged into a properly grounded outlet Plug both the Super Foam DomeTM and the pump from the barrel into the GFI Both units need to always come on at the same time o Never turn on the pump without the Super Foam DomeTM fan This will cause fluid to pour from fan area to floor Unplug the pump if you need to test only the fan When done switch GFI off and...

Page 9: ...xtension cords are 12 awg or larger and less than 100 feet long Unplug other equipment that is on the same circuit o If you are not getting fluid to the Super Foam DomeTM unit Check pump separately by disconnecting from the hose and by disconnecting the fan from the GFCI and turning on the unit for a short time If pump does not work check another power outlet If it still does not work replace unit...

Page 10: ...ia to grow Rinse and let the fan blow out the modulator after each use Never leave the modulator sock wet or dripping with solution 6 Service and Maintenance 6 1 Super Foam DomeTM Pump Information The Super Foam DomeTM pump has built in thermal overload protection which means the unit will automatically shut off when it overheats Once cooled down it will reset and is ready to pump again Power cord...

Page 11: ...TM Power Cord 6 1 9 m GFI Switch Box Four outlets with lighted power switch GFI Power Cord 6 1 9m Fluid pump High pressure diaphragm pump 45 psi 3 1 bar 1 4gpm 5 3 lpm Pump Power 120 VAC 60 Hz 0 7 A Pump Power Cord 6ft 1 9 m Type of Fluid Super Foam DomeTM fluid water mix Output 500 cubic feet per minute 14m3 min Fluid Consumption Approx 1 gallon per minute 3 8 l min Hose x 4 1 4cm x 1 2m pump hos...

Page 12: ...ation is not covered by this warranty Using any fluid other than what is recommended for this machine will void warranty No liability is accepted for injury or for loss damage or expense resulting from any interruption whatsoever in the operation of the product or from any consequential loss arising there from No liability is accepted for normal wear and tear We wish to satisfy YOU our customer an...

Page 13: ...reight costs to and from CITC when under the limited warranty services are the responsibility of the customer Customer must place appropriate insurance on return of product However if product is returned due to factory defect within the first year CITC will cover the cost of returning the repaired unit to the customer 6 Limited warranty services do not cause an extension of the limited warranty pe...