o If still clogged at the nozzle, remove unit to outside location and connect a high
pressure hose to the nozzle connection. While holding the unit in its hung position
so the water will run down and out of the unit, (not up or in the unit), turn on the
water to pressurize the nozzle inside and clean the nozzle. You should have
plenty of pressure and volume to remove any clogged item. If still clogged, send
the unit back to be serviced.
o
If the modulator appears to yellow or change color:
Dark areas that are warm are
easy for bacteria to grow. Rinse and let the fan blow out the modulator after each
use. Never leave the modulator (sock) wet or dripping with solution.
6. Service and Maintenance
6.1 Super Foam Dome
TM
Pump Information
The Super Foam Dome
TM
pump has built-in thermal overload protection, which means
the unit will automatically shut-off when it overheats. Once cooled down, it will reset and
is ready to pump again.
Power cord must always be plugged into the GFI. NEVER place pump in fluid!
Unplug or switch off the unit when fluid has drained to 1/8". Running the pump dry may
damage the pump.
6.2 Getting the most from your Super Foam Dome
TM
Pump
Optimum performance is reached at a maximum 25' tubing length, although the pump
continues to work at longer lengths.