Panel mounted sensor installation
Cistern mounted sensor
– Wave version only
Sensor gasket
Ø38mm
Apply
sanitary
silicone
sealant
Sensor nut
3 – 15mm
Ø44mm
Apply
sanitary
silicone
sealant
Sensor
gasket
Sensor nut
15 – 30mm
Apply
sanitary
silicone
sealant
M4
screw
Clamp plate
(reversible)
6mm packer
(See note*)
30 – 38mm
Side/front adaptor
NOTE:
For holes between 40 and 50mm contact
Cistermiser for a hole adapter. A hole diameter
larger than 50mm is a non standard installation.
Sensor gasket
Sensor
fastening nut
Sensor fixing
Mounting options
NOTE:
*If wall thickness is under 32mm use packer to prevent screw causing damage to sensor
NOTE:
Side/front adaptor required. Not supplied with
standard product but available as an extra.
Contact Cistermiser for further details or order
online at
www.cistermiser.co.uk
Thin wall
Medium thickness wall
Thick wall
6. Power Connections
Isolate mains power supply before proceeding. Mains wiring should be undertaken by a competent
person.
Battery Case – Open case and fit 4 x AA (LR-6) batteries. Use fittings provided or clip onto
Easyflush
EVO
Flush Valve.
Mains Adaptor – Fasten on a panel in a dry location using screws or sticky pads provided. Connect the
un-terminated cable to a 50Hz 230V AV single phase supply via a 1A fused spur (not supplied).
NOTE:
Remove sticky label from
sensor lens before use.
NOTE:
Either Battery
OR
Mains can
be connected, not both.
Multiple power connections for
Easyflush
EVO
If installing multiple Cistermiser products, the PSUC Multi Product Power Supply Unit is available as an
accessory. Contact Cistermiser for more details.
Multi product power supply unit
(Not supplied, contact Cistermiser for
further details). Suitable for powering
up to 10
Easyflush
EVO
units.
(2) Connect battery pack
OR
mains adaptor to IR Sensor
unit (2-way connector)
CAUTION:
Risk of electric shock.
Isolate supply before
working on wiring
(1) Connect IR Sensor
unit to Flush Valve
(3-way connector)
NOTE:
Always connect Sensor to Flush
Valve before connecting power.
Ø38mm