Wave sensing range adjustment
(this will restore default settings)
Wait for
1
x triple
red
LEDs to enter
wave/walkaway
setting
Sensor will flash single
central
green
LED
for wave mode
During the triple
red
flash briefly
place your hand in front of
the sensor.
The sensor will flash one central
green
LED to indicate wave function,
to change function put your hand in
front of the sensor for 3 second.
A
B
C
or double top/bottom
green
LEDs for walkaway mode
11. Advanced settings guide
Carry out only if settings need to be changed.
1
Disconnect power, wait for 5 seconds and reconnect.
When flashing triple
amber
.
If a hand is not placed over the sensor, it will go into normal operation mode.
Place hand 4-6cm from sensor
until constant
green
, then
remove hand.
You are now in configuration mode
2
3
After configuration the LEDs will flash triple
amber
, giving opportunity to re-enter configuration mode.
4
Wait for bottom
red
LED to enter sensing
range mode.
Briefly place your hand in front of
the sensor until the
green
LED
flashes slowly. Range configuration
mode will then be ready.
Move your hand to the distance from the sensor you would like
to set as maximum range. Wait 8 seconds until constant triple
green
LEDs show.
Sensor distance
is now set.
A
B
C
Wave sensing range adjustment
(when Wave variant is selected)
Refill duration adjustment
Wait for
4
x triple
red
LEDs to enter
refill time.
Once the cistern has refilled completely and the water has ceased to flow, move your hand
back into the line of sight of the sensor and triple
green
LEDs will show. The refill time has
now been set.
During the triple
red
flashing,
briefly place your hand in front of
the sensor. The valve will flush and
the cistern will refill. Triple
green
flashing LEDs will be seen.
A
B
C
NOTE:
Part flush is automatically set to approximately
⅔
of full flush
Full flush duration adjustment
Wait for
3
x
red
LEDs to enter flush
duration.
When the valve has flushed for the desired full flush time, move your hand out of the line of
sight of the sensor and triple
green
LEDs will show. The water will cease to flow and the
full flush time will be set.
During the triple
red
flashing
briefly place your hand in front
of the sensor. The valve will start
to flush and triple
green
flashing LEDs
will be seen. HOLD HAND STEADY.
A
B
C
Stand at the distance from the sensor you would
like to set as maximum range. Wait 8 seconds
until constant triple
green
LEDs show.
Sensor distance
is now set.
C
Wait for
2
x triple
red
LEDs to enter
sensing range mode.
Briefly place your hand in front of
the sensor until triple
green
LEDs
flash slowly. Range configuration
mode will then be ready.
A
B
Walkaway sensing range adjustment
(when Walkaway variant is selected)
X1
X3
X2