Wave sensing range adjustment

 (this will restore default settings)

Wait for 

1

 x triple 

red

 LEDs to enter 

wave/walkaway 

setting 

Sensor will flash single 

central 

green

 LED 

for wave mode

During the triple 

red

 flash briefly  

place your hand in front of 

the sensor.
The sensor will flash one central 

green

 LED to indicate wave function, 

to change function put your hand in 

front of the sensor for 3 second.  

A

B

C

or double top/bottom 

green

 

LEDs for walkaway mode

11. Advanced settings guide

Carry out only if settings need to be changed.

1

Disconnect power, wait for 5 seconds and reconnect.

When flashing triple 

amber

.

If a hand is not placed over the sensor, it will go into normal operation mode.

Place hand 4-6cm from sensor 

until constant 

green

, then 

remove hand.

You are now in configuration mode

2

3

After configuration the LEDs will flash triple 

amber

, giving opportunity to re-enter configuration mode.

4

Wait for bottom 

red

 

LED to enter sensing 

range mode.

Briefly place your hand in front of 

the sensor until the 

green

 LED 

flashes slowly. Range configuration 

mode will then be ready.

 

Move your hand to the distance from the sensor you would like 

to set as maximum range. Wait 8 seconds until constant triple 

green

 LEDs show.

Sensor distance 

is now set.

A

B

C

Wave sensing range adjustment

 (when Wave variant is selected)

Refill duration adjustment

Wait for 

4

 x triple  

red

 LEDs to enter 

refill time.

Once the cistern has refilled completely and the water has ceased to flow, move your hand 

back into the line of sight of the sensor and triple 

green

 LEDs will show. The refill time has 

now been set.

During the triple

 red 

flashing, 

briefly place your hand in front of 

the sensor. The valve will flush and 

the cistern will refill. Triple 

green

 

flashing LEDs will be seen.

A

B

C

NOTE: 

Part flush is automatically set to approximately 

 of full flush

Full flush duration adjustment

Wait for 

3

 x 

red

 

LEDs to enter flush 

duration.

When the valve has flushed for the desired full flush time, move your hand out of the line of 

sight of the sensor and triple 

green

 LEDs will show. The water will cease to flow and the 

full flush time will be set.

During the triple

 red 

flashing  

briefly place your hand in front  

of the sensor. The valve will start  

to flush and triple 

green

 flashing LEDs 

will be seen. HOLD HAND STEADY.

A

B

C

Stand at the distance from the sensor you would 

like to set as maximum range. Wait 8 seconds 

until constant triple 

green

 LEDs show.

Sensor distance 

is now set.

C

Wait for 

2

 x triple  

red

 LEDs to enter 

sensing range mode.

Briefly place your hand in front of 

the sensor until triple 

green

 LEDs 

flash slowly. Range configuration 

mode will then be ready.

 

A

B

Walkaway sensing range adjustment 

(when Walkaway variant is selected)

 

X1

X3

X2

Summary of Contents for Easyflush EVO 1.5

Page 1: ...EasyflushEVO EVO 1 5 EVO 2 EVO CISTERN SUSTAINABILITY A W A R D S 2 0 2 2...

Page 2: ...tem washer with boss 5 Outlet nut 6 Cap seal 7 Cap washer 8 Cap nut 9 Flush valve 10 IR Sensor unit 11 Sensor gasket 12 Sensor nut 13 Clamp plate 14 Screw packer 15 IR activation label walk wave 16 Ma...

Page 3: ...d water supply The flush is activated by the IR Sensor unit This can be configured to flush on a wave default or flush when the user walks away Wave default Walk Away Memory Flush If a flush is activa...

Page 4: ...f valve EasyflushEVO Flush Valve water level Unlock To adjust height of EasyflushEVO Flushing Valve rotate upper body clockwise to release Adjust Lift or lower upper body to adjust height Lock Rotate...

Page 5: ...ll Medium thickness wall Thick wall 6 Power Connections Isolate mains power supply before proceeding Mains wiring should be undertaken by a competent person Battery Case Open case and fit 4 x AA LR 6...

Page 6: ...nce per second Memory flush refilling Alternating 3 green LEDs rising Faulty wiring 2 red LEDs single flash once per second Low battery power fault 1 red LED single flash once per second NOTE For chem...

Page 7: ...DC regulated from mains adaptor 1A fused spur required Normal battery life 27 000 cycles Cleaning Clean with soap and water only Lens care Infrared lens can be polished with a soft cloth Electronic sp...

Page 8: ...onds until constant triple green LEDs show Sensor distance is now set A B C Wave sensing range adjustment when Wave variant is selected Refill duration adjustment Wait for 4 x triple red LEDs to enter...

Page 9: ...ively The sensor blinks red when the min or max value is reached Press the button to check the refill time setting the sensor displays the current setting by flashing green see table Save setting and...

Page 10: ...e float accordingly If the float is set too high water will continuously flow into the cistern and out of the overflow Cistermiser product warranty and extended warranty Cistermiser products are guara...

Page 11: ...or installation refer to advanced settings guide section 11 10 Test operation a Wave Place hand within 10cm of sensor for 1 second valve will part flush and the sensor will flash the single green LED...

Page 12: ...22 cistermiser co uk Have a question Call our customer support team on 0118 969 1611 Have a question Call our customer support team on 0118 969 1611 cistermiser co uk 23 Notes...

Page 13: ...commercial and industrial applications worldwide keraflo co uk Combimate is a domestic limescale prevention device that prevents limescale build up and soft water corrosion in combination boilers and...

Reviews: