9. Usage advice and specification

Factory settings

Range (EF Wave):

 

 

~10cm

Range (EF Walkaway):  

~55cm (~6cm for hand activation)

Refill duration after part flush:

 

 

40 seconds

Refill duration after full flush:

 

 

60 seconds

Part flush duration:

 

 

2¾ seconds

Full flush duration:

 

 

6 seconds

Power requirements:

 

  

Either 6V from 4 x alkaline AA (LR6) batteries or 6V DC  

regulated from mains adaptor (1A fused spur required)

Normal battery life:

 

  

27 000 cycles

Cleaning:

 

 

Clean with soap and water only

Lens care:  

Infrared lens can be polished with a soft cloth

Electronic specification

Control classification:  

Independent

Maximum load:  

1A (6W) at 6VDC

Rated temperature range:  

0-40 °C

Mains power supply:  

100-250V AC 50/60Hz 1A MAX

Fill Valve (supplied with EVO CISTERN only)

Minimum working pressure:  

0.1 bar

Maximum working pressure:  

10 bar

10. Component dimensions

EVO 1.5

"

 & EVO 2

"

 

EVO CISTERN

 446

 263 

 316.

5

TO BOTTOM OF CISTER

N

 200.00 

 

30

6 LITRE

CRITICAL

WATER

LEVEL

 119.5

 122.5 - 182.5  WATER LEVEL

 101

 OVERALL HEIGHT RANGE 239.5 - 299.5 

60mm HEIGHT ADJUSTMENT

 EVO - 1.5" outlet 

EVO 2 - 2.0" outlet

Summary of Contents for Easyflush EVO 1.5

Page 1: ...EasyflushEVO EVO 1 5 EVO 2 EVO CISTERN SUSTAINABILITY A W A R D S 2 0 2 2...

Page 2: ...tem washer with boss 5 Outlet nut 6 Cap seal 7 Cap washer 8 Cap nut 9 Flush valve 10 IR Sensor unit 11 Sensor gasket 12 Sensor nut 13 Clamp plate 14 Screw packer 15 IR activation label walk wave 16 Ma...

Page 3: ...d water supply The flush is activated by the IR Sensor unit This can be configured to flush on a wave default or flush when the user walks away Wave default Walk Away Memory Flush If a flush is activa...

Page 4: ...f valve EasyflushEVO Flush Valve water level Unlock To adjust height of EasyflushEVO Flushing Valve rotate upper body clockwise to release Adjust Lift or lower upper body to adjust height Lock Rotate...

Page 5: ...ll Medium thickness wall Thick wall 6 Power Connections Isolate mains power supply before proceeding Mains wiring should be undertaken by a competent person Battery Case Open case and fit 4 x AA LR 6...

Page 6: ...nce per second Memory flush refilling Alternating 3 green LEDs rising Faulty wiring 2 red LEDs single flash once per second Low battery power fault 1 red LED single flash once per second NOTE For chem...

Page 7: ...DC regulated from mains adaptor 1A fused spur required Normal battery life 27 000 cycles Cleaning Clean with soap and water only Lens care Infrared lens can be polished with a soft cloth Electronic sp...

Page 8: ...onds until constant triple green LEDs show Sensor distance is now set A B C Wave sensing range adjustment when Wave variant is selected Refill duration adjustment Wait for 4 x triple red LEDs to enter...

Page 9: ...ively The sensor blinks red when the min or max value is reached Press the button to check the refill time setting the sensor displays the current setting by flashing green see table Save setting and...

Page 10: ...e float accordingly If the float is set too high water will continuously flow into the cistern and out of the overflow Cistermiser product warranty and extended warranty Cistermiser products are guara...

Page 11: ...or installation refer to advanced settings guide section 11 10 Test operation a Wave Place hand within 10cm of sensor for 1 second valve will part flush and the sensor will flash the single green LED...

Page 12: ...22 cistermiser co uk Have a question Call our customer support team on 0118 969 1611 Have a question Call our customer support team on 0118 969 1611 cistermiser co uk 23 Notes...

Page 13: ...commercial and industrial applications worldwide keraflo co uk Combimate is a domestic limescale prevention device that prevents limescale build up and soft water corrosion in combination boilers and...

Reviews: