Page 20
Steam Piping - Installation Instructions
STEAM PIPING -
1. Set and anchor dryer in position. Machine should be level
INSTALLATION
assure proper steam circulation.
INSTRUCTIONS
2. To prevent condensate draining from headers to dryer,
piping should have a minimum 12 (305 mm)above respective
header. Do not make steam connection to header with a
horizontal or downwardly facing tee or elbow.
3. Whenever possible, horizontal runs of steam lines must
drain, by gravity, to respective steam header. Water
pockets, or an improperly drained steam header will
provide wet steam, causing improper operation of dryer. If
pockets or improper drainage cannot be eliminated, install
a by-pass trap to drain condensate from the low point in the
steam supply header to the return.
4. In both steam supply and steam return line, it is
recommended that each have a 3/4(20 mm) union and 3/4
(20 mm) globe valve. This will enable you to disconnect the
steam connections and service the dryer while your plant is in
operation.
5. Before connecting trap and check valve to dryer, open globe
valve in steam supply line and allow steam to flow through
dryer to flush out any dirt and scale from dryer. This will
assure proper operation of trap when connected.
6. After flushing system, install bucket trap (with built-in
strainer) and check valve. For successful operation of dryer,
install trap 18" (458 mm) below coil and as near to the dryer as
possible. Inspect trap carefully for inlet and outlet
markings and install according to trap manufacturer's
instructions. If steam is gravity returned to boiler, omit
trap but install check valve in return line near dryer.
7. Install union and globe valve in return line and make final
pipe connections to return header.
PIPING
1. Trap each dryer individually. Always keep the trap clean
RECOMMENDATIONS
and in good working condition.
2. When dryer is on the end of a line of equipment, extend header
at least 4 feet (2 m)beyond dryer. Install gloge valve, union,
check valve and by-pass trap at end of line. If gravity return to
boiler, omit trap.
3. Insulate steam supply and return line for safety of operator and
safety while servicing dryer.
4. Keep dryer in good working condition. Repair or replace any
worn or defective parts.
Summary of Contents for HD150.1
Page 10: ...Page 10 150 lb Gas Fired Dryer Illustration ...
Page 13: ...Page 13 Gas Piping Installation Illustration ...
Page 15: ...Page 15 150 lb Steam Heated Models Illustration ...
Page 22: ...Page 22 Dryer Installation with Multiple Exhaust Illustration ...
Page 30: ...Page 30 Two Timer Models Figures 1 2 and 3 Illustrations ...
Page 38: ...Page 38 DIRECT SPARK IGNITION OPERATION FLOW CHART ...
Page 42: ...Page 42 Basket Alignment for 150 lb Dryers Illustrations ...
Page 44: ...Page 44 Shimming the Basket and Spider Assembly Illustration ...
Page 67: ...Page 67 ...