32
5
Technical
remarks
Gas
failure
The
electronic
ignition
of
a
gas-heated
dryer
will
only
try
to
function
once
for
about
10
seconds.
If
this
fails
and
the
detection-device
doesn
'
t
detect
any
flame
(for
example
in
case
of
a
gas
failure),
then
the
ignition
relay
goes
into
safety.
When
the
drying
cycle
restarts
,
then
a
new
ignition
will
occur.
Electronic
temperature
protection
When
a
temperature
of
4
°
C
or
less,
or
of
100
°
C
or
more
has
been
detected,
the
electronic
temperature
protection
will
be
activated.
During
operation
:
Temperature
higher
than
100
°
C
:
The
heating
is
interrupted,
but
the
cycle
is
completely
finished.
The
display
reads
"ESH"
.
Temperature
lower
than
4
°
C
:
When
after
3
minutes
a
temperature
lower
than
4
°
C
is
detected,
the
heating
will
be
interrupted.
The
cycle
is
completely
finished
and
the
display
reads
"EOP"
.
Sail
switch
In
case
the
drum
no
longer
rotates
due
to
failure
(for
instance
breakdown
of
a
V-
belt),
"
rot
"
will
appear
blinking
on
the
display
if
the
machine
is
equipped
with
a
rotation
sensor
(option)
and
the
cycle
continues
without
activating
the
heating.
The
rotation
sensor
is
fixed
at
the
back
of
the
dryer
near
the
drum
axle.
The
sail
switch
is
in
the
back
and
is
a
protection,
which
interrupts
the
heating,
in
case
there
is
insufficient
air
supply.
This
can
be
the
result
of
an
inadequate
exhaust,
of
a
dirty
filter.
It
is
necessary
that
the
sail
switch
can
move
freely.
In
case
of
a
malfunction,
"
VEn
"
appears
blinking
on
the
display
and
the
cycle
continues
without
activating
the
heating.
Rotation
sensor
Summary of Contents for DX4 CONTROLLER
Page 2: ......
Page 4: ...4 ...
Page 8: ...8 3 ...
Page 10: ...10 3 ...
Page 12: ...12 3 ...
Page 14: ...14 3 ...
Page 16: ...16 3 ...
Page 18: ...18 3 ...
Page 20: ...20 3 ...
Page 22: ...22 3 ...
Page 24: ...24 3 ...
Page 26: ...26 3 ...
Page 34: ...34 ...
Page 35: ...35 ...
Page 36: ......