Multichannel STM-1 Port Adapter for the Cisco 7500 Series Router
Configuration Tasks
14
12.0(14)S
Verifying the Configuration
You can verify the configuration and status of the controller by using the
show controller
commands as
detailed below.
When AUG mapping is AU-4, view information about the SONET controller using the
sonet controller sonet
port/port-adapter/port
[
brief
|
tabular
] command.
Router#
show controller sonet 2/0/0
SONET 2/0/0 is up.
Channelized OC-3/STM-1 SMI PA
H/W Version :0.2.3, ROM Version :1.2
FREEDM version :2, F/W Version :1.2.0
Applique type is Channelized Sonet/SDH
Clock Source is Internal, AUG mapping is AU4.
Medium info:
Type:SDH, Line Coding:NRZ, Line Type:Short SM
Regenerator Section Status:
No alarms detected.
Multiplex Section Status:
No alarms detected.
Higher Order Path Status:
Path# 1 has no defects
Lower Order Path Status:
VC-12 1/1/1/1 has no defects
VC-12 1/1/1/2 has no defects
VC-12 1/1/1/3 has no defects
VC-12 1/1/2/1 has no defects
VC-12 1/1/2/2 has no defects
VC-12 1/1/2/3 has no defects
[display text omitted]
Data in current interval (137 seconds elapsed):
Regenerator Section:
0 CVs, 0 ESs, 0 SESs, 0 SEFSs
Multiplex Section:
0 CVs, 0 ESs, 0 SESs, 0 UASs
Higher Order Path:
Path# 1: 0 CVs, 0 ESs, 0 SESs, 0 UASs
Lower Order Path:
VC-12 1/1/1/1: 0 CVs, 0 ESs, 0 SESs, 0 UASs
VC-12 1/1/1/2: 0 CVs, 0 ESs, 0 SESs, 0 UASs
VC-12 1/1/1/3: 0 CVs, 0 ESs, 0 SESs, 0 UASs
VC-12 1/1/2/1: 0 CVs, 0 ESs, 0 SESs, 0 UASs
[display text omitted]
SONET 2/0/0 E1 1/1/1/1 is up
No alarms detected.
Framing is crc4, Clock Source is internal, National bits are 0x1F.
Data in current interval (137 seconds elapsed):
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs
0 Unavail Secs
SONET 2/0/0 E1 1/1/1/2 is up
No alarms detected.
Framing is crc4, Clock Source is internal, National bits are 0x1F.