Chapter 4 Managing the Cisco SFS 7000P Switch
Displaying System Information
4-8
Cisco SFS 7000P Hardware Installation Guide
OL-9167-01 Rev. A0
================================================================================
Fan Seeprom
================================================================================
product pca pca fru
fan serial-number serial-number number number
--------------------------------------------------------------------------------
1
2
3
4
SFS-7000P#
Displaying Sensor Information
To display information about the sensors, enter the
show sensor
command.
SFS-7000P# show sensor
================================================================================
Sensor Information
================================================================================
sensor oper-status oper-code temperature(c) alarm-temp(c) shutdown-temp(c)
--------------------------------------------------------------------------------
1/1 up normal 29 65 73
SFS-7000P#
In the
Temperature
field, the internal system temperature is displayed in Celsius.
The system’s maximum external ambient temperature is 30 degrees Celsius (0 –
10,000 feet). Acceptable internal temperature ranges are 30 degrees Celsius above
external ambient, plus 1 degree for every 1,000 feet above sea level.
A warning will appear if the temperature reaches 65 degrees Celsius (at sea level).
The system reboots at an internal temperature of 75 degrees Celsius (at sea level).