3-2
Cisco SFS 7000P Hardware Installation Guide
OL-9167-01 Rev. A0
Chapter 3 Installing Field Replaceable Units
Installing a Power Supply or Fan Unit
Failed Power Supplies or Fan Units
The status of power supplies and fan units can be checked using the CLI, the
Chassis Manager, or the Element Manager. The available information includes the
status, the vital product data (VPD), the description of the error or an error code.
If you suspect that a power supply module has failed, check the LEDs (see the
“Power Supply and Fan LEDs” section on page 4-3
) and view the status through
the Element Manager.
In most cases, vital information can be retrieved from the console port of
management Ethernet port. See the
“Vital Product Data Storage” section on
page 1-5
.
Refer to the
Cisco SFS 7000 Series Product Family Chassis Manager User Guide
or
Cisco SFS 7000 Series Product Family Element Manager User Guide
for more
information.
Installing a Power Supply or Fan Unit
Caution
Never place your hand inside an empty module bay or anywhere inside the Cisco
SFS 7000P switch.
Caution
Unused module bays should always have a Cisco SFS 7000P filler panel over the
bay to ensure proper safety, ventilation, and cooling.
To insert a power supply or fan unit, follow these steps:
Step 1
Ground yourself appropriately.
Step 2
Remove the filler panel from the power supply bay with a number 1 Phillips
screwdriver, if it is still in place (see
Figure 3-1
).
Summary of Contents for SFS 7000P