Configuring Fabric Binding
The fabric binding feature ensures ISLs are only enabled between specified switches in the fabric binding
configuration. Fabric binding is configured per VSAN.
Configuring Fabric Binding
You can configure fabric binding in each switch in the fabric.
Procedure
Step 1
Enable the fabric configuration feature.
Step 2
Configure a list of sWWNs and their corresponding domain IDs for devices that are allowed to access the
fabric.
Step 3
Activate the fabric binding database.
Step 4
Copy the fabric binding active database to the fabric binding configuration database.
Step 5
Save the fabric binding configuration.
Step 6
Verify the fabric binding configuration.
Enabling Fabric Binding
You can enable fabric binding on any participating switch.
Procedure
Purpose
Command or Action
Enters global configuration mode.
configure terminal
Example:
switch# configure terminal
switch(config)#
Step 1
Enables fabric binding on that switch.
feature fabric-binding
Example:
switch(config)# feature fabric-binding
Step 2
Switch WWN Lists
A user-specified fabric binding list contains a list of switch WWNs (sWWNs) within a fabric. If an sWWN
attempts to join the fabric, and that sWWN is not on the list or the sWWN is using a domain ID that differs
Cisco Nexus 5500 Series NX-OS SAN Switching Configuration Guide, Release 7.x
OL-30895-01
269
Configuring Fabric Binding
Configuring Fabric Binding