Step 2
Connect the outside network to the Ethernet1/1 interface (labeled WAN).
By default, the IP address is obtained using IPv4 DHCP and IPv6 autoconfiguration, but you can set a static
address during initial configuration.
Step 3
Connect other networks to the remaining interfaces.
Power on the Device
The power switch is located to the left of power supply module 1 on the rear of the chassis. It is a toggle
switch that controls power to the system. If the power switch is in standby position, only the 3.3-V standby
power is enabled from the power supply module and the 12-V main power is OFF. When the switch is in the
ON position, the 12-V main power is turned on and the system boots.
Before you begin
It's important that you provide reliable power for your device (for example, using an uninterruptable power
supply (UPS)). Loss of power without first shutting down can cause serious file system damage. There are
many processes running in the background all the time, and losing power does not allow the graceful shutdown
of your system.
Procedure
Step 1
Attach the power cord to the device and connect it to an electrical outlet.
Step 2
Press the power switch on the back of the device.
Step 3
Check the PWR LED on the front of the device; if it is solid green, the device is powered on.
Step 4
Check the SYS LED on the front of the device; after it is solid green, the system has passed power-on
diagnostics.
Before you move the power switch to the OFF position, use the shutdown commands so that the
system can perform a graceful shutdown. This may take several minutes to complete. After the
graceful shutdown is complete, the console displays
It is safe to power off now
. The front
panel blue locator beacon LED lights up indicating the system is ready to be powered off. You can
now move the switch to the OFF position. The front panel PWR LED flashes momentarily and turns
off. Do not remove the power until the PWR LED is completely off.
See the
for more information on using the shutdown commands.
Note
Cisco Firepower 2100 Getting Started Guide
11
Firepower Threat Defense Deployment with FDM
Power on the Device
Summary of Contents for Firepower 2100
Page 2: ......
Page 166: ......
Page 191: ...Cisco Firepower 2100 Getting Started Guide 189 ASA Deployment with ASDM End to End Procedure ...
Page 221: ... 2021 Cisco Systems Inc All rights reserved ...
Page 222: ......