Step 3
Connect the type-A USB connector of the console cable to the Exar XR21V1410 UART with USB interface.
Step 4
Connect the Exar XR21V1410 UART to the appropriate serial port on the PC or terminal using a cable with type-A USB
connector on one end and DB-9 connector on the other end.
Step 5
Power up the PC or terminal.
Step 6
Configure the PC terminal emulation software or the terminal with the following settings:
•
9600 baud
•
8 data bits
•
No parity generation or checking
•
1 stop bit
•
No flow control
Swap Supervisor 160G to Supervisor 250G 10GE Mode
Backup the Configuration and IOS Code
Step 1
Insert the Cisco certified eUSB disk into the USB0 on the active SUP160 board.
Step 2
Edit the configuration follow the steps below:
Please note that on SUP250, all 10G and 100G interfaces are visible regardless of whether the related QSFP module is
inserted or not. The backhaul interface numbering scheme on SUP250 is different from SUP160, shown as below:
10GE interface
100GE interface
Te4/1/2 ~ Te4/1/9
Hu4/1/0 ~ Hu4/1/1
SUP4
Te5/1/2 ~ Te5/1/9
Hu5/1/0 ~ Hu5/1/1
SUP5
Therefore, we recommend the user to copy the SUP160 configuration out to the server and edit the SUP160 configuration
manually before copy back to the SUP250.
a) Replace the card type
sup-pic-8x10g
with
sup-pic-2x100g-8x10g
on both card 4/1 and 5/1.
card 0/0 cBR-CCAP-LC-40G r-phy
card 1/0 cBR-CCAP-LC-40G r-phy
card 2/0 cBR-CCAP-LC-40G
card 3/0 cBR-CCAP-LC-40G
card 4/1 sup-pic-2x100g-8x10g
card 5/1 sup-pic-2x100g-8x10g
card 6/0 cBR-CCAP-LC-40G
card 7/0 cBR-CCAP-LC-40G
Cisco Converged Broadband Routers Hardware Installation Guide
30
Installing the Supervisor in the Cisco cBR Chassis
Swap Supervisor 160G to Supervisor 250G 10GE Mode