enable
–
Enables logging for a specific instance or all instances. This keyword is only supported for
aaamgr, hamgr and sessmgr facilities. By default logging is enabled for all instances of aaamgr, hamgr
and sessmgr.
•
facility facility
and
level severity_level
–
Configure the logging filter that determines which system
facilities should be logged and at what levels. For detailed information, see
page 132
and
Event Severities, on page 157
.
•
all | instance instance_number
–
Specifies whether logging will be disabled or enabled for all instances
or a specific instance of aaamgr, hamgr or sessmgr. Run the
show session subsystem facility facility
command to identify specific instance numbers.
These keywords are only supported with the
disable
and
enable
keywords.
Note
•
level severity_level
–
Specifies the level of information to be logged from the following list which is
ordered from highest to lowest:
•
critical - display critical events
•
error - display error events and all events with a higher severity level
•
warning - display warning events and all events with a higher severity level
•
unusual - display unusual events and all events with a higher severity level
•
info - display info events and all events with a higher severity level
•
trace - display trace events and all events with a higher severity level
•
debug - display all events
This keyword is only supported in conjunction with the
active
keyword.
Note
•
critical-info
–
Specifies that events with a category attribute of critical information are to be displayed.
Examples of these types of events can be seen at bootup when system processes and tasks are being
initiated. This is the default setting.
no-critical-info
–
Specifies that events with a category attribute of critical information are not to be
displayed.
These keywords are only supported in conjunction with the
active
keyword.
Note
To enable logging of a single instance of a facility, you must first disable all instances of the facility
(
logging filter disable facility facility all
) and then enable logging of the specific instance (
logging filter
enable facility facility instance instance_number
. To restore default behavior you must re-enable logging
of all instances (
logging filter enable facility facility all
).
Important
ASR 5500 System Administration Guide, StarOS Release 21.5
129
System Logs
Configuring Event Log Filters