Basic Configuration Using the Command-Line Interface
Configuring Clocking
33
Cisco AS5350XM and Cisco AS5400XM Universal Gateways Software Configuration Guide
-------------------------------------------------------------
Trunk cards controllers clock health information
------------------------------------------------
Slot Type 7 6 5 4 3 2 1 0
1 T1 B B B B B B B B
CLOCK CHANGE HISTORY
--------------------------
CLOCK Event Time
----- ----- ----
1/1 Loss Of Signal (LOS) 00:00:22 UTC Tue Nov 30 1999
1/2 Loss Of Signal (LOS) 00:00:22 UTC Tue Nov 30 1999
1/3 Alarm Indication Signal (AIS) 00:00:22 UTC Tue Nov 30 1999
1/4 Alarm Indication Signal (AIS) 00:00:22 UTC Tue Nov 30 1999
1/5 Alarm Indication Signal (AIS) 00:00:22 UTC Tue Nov 30 1999
1/6 Alarm Indication Signal (AIS) 00:00:22 UTC Tue Nov 30 1999
1/7 Alarm Indication Signal (AIS) 00:00:22 UTC Tue Nov 30 1999
AS5400#
•
Verify your TDM clock history using the
show tdm clocks
command (this example is for
channelized T3):
AS5400#
show tdm clocks
Primary Clock:
--------------
System primary is slot 7 ds3_port 0 ds1_port 1 of priority 1
TDM Bus Master Clock Generator State = NORMAL
Backup clocks for primary:
Source Slot Port DS3-Port Priority Status State
-------------------------------------------------------------
Trunk 7 8 YES 214 Good Default
Trunk 7 9 YES 215 Good Default
Trunk cards controllers clock health information
------------------------------------------------
CT3 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1
Slot Port Type 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1
7 0 T3 G G G G G G G G G G G G G G G G G G G G G G G G G G G G
CLOCK CHANGE HISTORY
--------------------------
CLOCK Event Time
----- ----- ----
7/1 Signal recovered from LOS 00:03:29 UTC Sat Jan 1 2000
7/8 Alarm Indication Signal (AIS) 11:27:48 UTC Fri Feb 25 2000
7/1 Signal recovered from LOS 11:30:22 UTC Fri Feb 25 2000
AS5400#
•
Verify your user-configured trunk clock selection using the
show tdm clocks
command:
AS5400#
show tdm clocks
Primary Clock:
System primary is slot 2 port 0 of priority 15
TDM Bus Master Clock Generator State = NORMAL
Backup clocks for primary: