B-9
Firepower 8000 Series Hardware Installation Guide
Appendix B Inserting and Removing Firepower 8000 Series Network Modules
Restart the Appliance
Restart the Appliance
Before You Begin
•
Plug in all power cords to the appliance.
•
Wait until the appliance is fully powered up. This could take several minutes.
Procedure
Step 1
Choose
System > Configuration
.
Step 2
Choose
Process
.
Step 3
Click
Run Command
next to
Restart Appliance Console
.
Verify the NetMod from the Firepower Management Center
Procedure
Step 1
Choose
Devices > Device Management
.
Step 2
Next to the device where you want to view the interfaces, click the edit icon (
).
Step 3
Verify the interfaces on the
Interfaces
tab.
Step 4
If your appliance is part of a device stack or high-availability pair, bring the device out of maintenance
mode from the Firepower Management Center:
•
Choose
Devices > Device Management
.
•
Next to the stack member or peer, click the toggle maintenance mode icon (
) to bring the device
out of maintenance mode.
What to Do Next
•
Configure the new interfaces. See the “Interface Configuration Settings” chapter in the
Firepower
Management Center Configuration Guide
.
•
Apply the configuration changes.
Apply Changes to the Appliance
After you make changes to the configuration of a device, a device cluster, or a device stack, you must
apply the changes before they take effect throughout the system. Note that the device must have
unapplied changes or this option remains disabled.
Note that if you edit interfaces and reapply a device policy, Snort restarts for all interface instances on
the device, not just those that you edited.