Step 12
Prior to attaching the access point to the mounting plate, ensure that the radio modules are completely
inserted and both module latches are in the locked position (see
Figure 2-24
).
Step 13
Attach the access point to the mounting plate (see the
“Mounting Plate Attached to a Surface” section
on page 2-26
).
Step 14
Connect the antennas or antenna cables to the access point connectors and hand-tighten. Ensure the
2.4-GHz antennas or antenna cables are connected to the access point’s 2.4-GHz antenna connectors (see
Figure 1-1 on page 1-3
).
Note
The access point 5-GHz antenna connectors have a blue label to correspond with the blue dot or
label on the Cisco Aironet 5-GHz antennas or antenna cables.
Step 15
If you need additional security, see the
“Securing the Access Point” section on page 2-27
for additional
information.
Step 16
Verify the access point is operating before replacing the ceiling tile (see the
“Powering Up the Access
Point” section on page 2-22
).
Installing Option Two
Option two consists of two B-Line mounting systems mounted on each end of the mounting bracket. The
steps are basically the same as those in the
“Installing Option One” section on page 2-13
except that the
box hangers are positioned as shown in Figures
2-9
and
2-10
.
Figure 2-9
Left Side Box Hanger Mounting Details (B-Line)
276482