Step 5
Hook one end of the copper wire around the screw on the rack.
Step 6
Tighten the rack screw over the copper wire.
Note
You can use a lug terminal to connect the grounding wire to the rack.
Step 7
Loosen the compression screw that is provided on the grounding lug of the Cisco 6130.
The grounding lugs are located in the upper left corner of each chassis (viewed from the rear).
Step 8
Insert the other end of the copper wire under the compression screw.
Step 9
Tighten the compression screw over the copper wire.
Note
Do not ground the components in a rack by chaining them together.
The left side of Figure 11 shows how to ground the Cisco 6130 chassis.
Figure 11
Grounding the Cisco 6130 Chassis
Connect the Cisco 6130 to the Cisco 6120
Connect the one-to-two Champ cables from the Cisco 6100 (connectors J39 through J44) to the
Cisco 6120 (connectors J1 through J6). Table 3 shows the corresponding Cisco 6100 and Cisco 6120
connectors when two Cisco 6120 chassis are used.
Rack
Cisco 6100/6130
43434
Table 3
Cisco 6100 and Cisco 6120 Corresponding Connectors
Cisco 6100
Connector
First
Cisco 6120
Connector
Second
Cisco 6120
Connector
J39
J3
J3
J40
J1
J1
J41
J5
J5
J42
J4
J4
J43
J2
J2
J44
J6
J6