Chapter 6 Router Field Diagnostics
Field-Programmable Gate Array Overview
6-6
Cisco 12010, Cisco 12410, and Cisco 12810 Router Installation and Configuration Guide
OL-11496-01
Step 2
Enter the
diag
slot-number
update-fpga source
{
tftp | flash
}
source-path
command to update the flash memory.
Where:
•
slot-number
is the slot number of the line card you are upgrading.
•
source-path
is the path to the diagnostic image.
–
For flash memory cards, the source path is typically:
slot0:c12k-fdiagsbflc-mz.
120-25.S
or
slot1:c12k-fdiagsbflc-mz.
120-25.S
.
–
For TFTP boot servers, the source path is typically:
tftp://
tftp_server_ip_address/my_directory
/c12k-fdiagsbflc-mz.
120-25
.S
.
Caution
Do not unplug the line card or terminate the field diagnostics session during this
test.
The following example shows the output of a line card with the
update-fpga
option specified.
Router#
diag 7 verbose source tftp
tftp://223.255.254.254/c12k-fdiagsbflc-mz.120-25.S update-fpga
Running DIAG config check
Fabric Download for Field Diags chosen: If timeout occurs, try 'mbus'
option.
Verbose mode: Test progress and errors will be displayed
UUT will update FPGA's flash
Runnning Diags will halt ALL activity on the requested slot.
[confirm]
Router#
PID of f_diag_run is 121, set test_pid[3]
gdb slot is 0
Launching a Field Diagnostic for slot 7
Loading c12k-fdiagsbflc-mz.new_fpga from 223.255.254.254 (via
Ethernet0):
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
Calling enable_slot_and_type_on_fabric(DISABLE) for slot 7
Calling enable_slot_and_type_on_fabric(ENABLE) for slot 7
FD 3> *****************************************************
FD 3> GSR Field Diagnostics V6.9